General Information
Version
1.3
Revision date
2025-11-19
Product name
BC HVO Biodiesel
CAS No.
928771-01-1
1.2.1 Relevant identified uses
Fuel for use in diesel powered engines
Emergency telephone
1-800-240-6737, 1-855-697-4355
Icons in SDS
Company Information
company name
Shell Chemical LP
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
Aspiration hazard
Category 1
Signal word
Danger
Physical hazards
H226 Flammable liquid and vapour
Health hazards
H304 May be fatal if swallowed and enters airways
Environmental hazards
Not classified as an environmental hazard under GHS criteria
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ ventilating/ lighting equip- ment. P242 Use only non-sparking tools. P243 Take action to prevent static discharges. P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
Response
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower. P370 + P378 In case of fire: Use appropriate media to extin- guish. P331 Do NOT induce vomiting.
Storage
P403 + P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.
Disposal
P501 Dispose of contents/ container to an approved waste dis- posal plant.
Other hazards which do not result in classification
Slightly irritating to respiratory system. High concentrations may cause central nervous system depression resulting in headaches, dizzi- ness and nausea. Repeated exposure may cause skin dryness or cracking. May ignite on surfaces at temperatures above auto-ignition temperature. Vapour in the headspace of tanks and containers may ignite and explode at temperatures ex- ceeding auto-ignition temperature, where vapour concentrations are within the flammability range. Electrostatic charges may be generated during pumping. Electrostatic discharge may cause fire. This material is a static accumulator. Even with proper grounding and bonding, this material can still accumulate an electrostatic charge. If sufficient charge is allowed to accumulate, electrostatic discharge and ignition of flammable air- vapour mixtures can occur.
2.1 Classification of the substance or mixture
1910.1200) Flammable liquids : Category 3 Aspiration hazard