Note: Ingredients listed on restricted chemical lists
EC/CAS
110-18-9
Name of the chemical
N,N,N',N'-tetramethylethylenediamine
Concentration
N/A
General Information
Revision date
2012-06-11
Product name
Acrylamide Polymerisation Sachet
1.2.1 Relevant identified uses
SU24 Scientific research and development
Emergency telephone
0044 1562 825286 (not 24 hours
Icons in SDS
Company Information
company name
Severn Biotech Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
info@severnbiotech.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H314, H317, H318, H334
Hazard statements
Code
Statements
H314
Causes severe skin burns and eye damage
Section 2
CLP CLASSIFICATION
GHS08 health hazard Resp. Sens. 1 H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. GHS05 corrosion Skin Corr. 1B H314 Causes severe skin burns and eye damage. Eye Dam. 1 H318 Causes serious eye damage. GHS07 Skin Sens. 1 H317 May cause an allergic skin reaction.
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS05, GHS08
Signal word
Danger
Hazardous Ingredients
N,N,N',N'-tetramethylethylenediamine Ammonium persulphate
Hazard statements
H314 Causes severe skin burns and eye damage. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317 May cause an allergic skin reaction.
Precautionary statements
P260 Do not breathe dust/fume/gas/mist/vapours/spray. P280 Wear protective gloves/protective clothing/eye protection/face protection. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P302+P352 IF ON SKIN: Wash with plenty of soap and water.
PBT Substances
Not applicable
vPvB Substances
Not applicable