Note: Ingredients listed on restricted chemical lists
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
35-38
EC/CAS
7727-37-9
Name of the chemical
Nitrogen N2
Concentration
0.0001-3
General Information
Revision date
2019-09-25
Product name
PTG-4291
Product Synonyms
Carbon Dioxide (35-38%), Nitrogen (0.0001-3%), Hydrogen Sulfide (0.0001-1.7%), in Methane
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Scientific Gas Australia Pty Ltd
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H400
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
Classification (GHS-US)
Flam. Gas 1 H220 Press. Gas (Liq.) H280 Aquatic Acute 1 H400
2.2 Label elements
GHS AU labelling
Hazard pictograms
GHS02 GHS04 GHS09
Signal word
GHS-AU) : DANGER
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H400 - VERY TOXIC TO AQUATIC LIFE CGA-HG03 - MAY INCREASE RESPIRATION AND HEART RATE. CGA-HG04 - MAY FORM EXPLOSIVE MIXTURES WITH AIR
Precautionary statements
P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P391 - Collect spillage P403 - Use and store only outdoors or in a well-ventilated place. P261 - Avoid breathing gas P271+P403 - Use and store only outdoors or in a well-ventilated place. CGA-PG27 - Read and follow the Safety Data Sheet (SDS) before use. CGA-PG21 - Open valve slowly. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG11 - Never put cylinders into unventilated areas of passenger vehicles. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG06 - Close valve after each use and when empty. EN (English - AU) CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). CGA-MP01 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Get medical advice/attention. P273 - Avoid release to the environment. P501 - Dispose of contents/container in accordance with local/regional/national/international regulations. Contact supplier for any special requirements.
Other hazards which do not result in classification
Asphyxiant in high concentrations. 2.4.
Ingredient(s) with unknown acute toxicity