Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-59-7
Name of the chemical
Helium He
Concentration
24.9-84.6
EC/CAS
630-08-0
Name of the chemical
Kohlenmonoxid
Concentration
15.4-75.1
General Information
Revision date
2019-09-25
Product name
PTG-4075
Substance name
PTG-4075
1.2.1 Relevant identified uses
Calibration / Reference
Emergency telephone
Onsite Emergencies 1-800-645-4633; Australian
Icons in SDS
Company Information
company name
Scientific Gas Australia Pty Ltd
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H332, H360, H372
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
Classification (GHS-US)
Flam. Gas 1 H220 Press. Gas (Comp.) H280 Acute Tox. 4 (Inhalation:gas) H332 Repr. 1A H360 STOT RE 1 H372
2.2 Label elements
GHS AU labelling
Hazard pictograms
GHS02 GHS04 GHS07 GHS08
Signal word
GHS-AU) : DANGER
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H332 - HARMFUL IF INHALED H360 - MAY DAMAGE FERTILITY OR THE UNBORN CHILD H372 - CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE
Precautionary statements
P271+P403 - Use and store only outdoors or in a well-ventilated place. P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P260 - Do not breathe gas/vapors P261 - Avoid breathing gas, vapors P264 - Wash exposed skin thoroughly after handling P270 - Do not eat, drink or smoke when using this product P280 - Wear protective gloves/protective clothing/eye protection/face protection P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. EN (English - AU) P308+P313 - If exposed or concerned: Get medical advice/attention P311 - Call a poison center/doctor/… P314 - Get medical advice/attention if you feel unwell P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P405 - Store locked up P410+P403 - Protect from sunlight. Store in a well-ventilated place. P501 - Dispose of contents/container in accordance with local/regional/national/international regulations. Contact supplier for any special requirements. CGA-PG27 - Read and follow the Safety Data Sheet (SDS) before use. CGA-PG21 - Open valve slowly. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG06 - Close valve after each use and when empty. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG11 - Never put cylinders into unventilated areas of passenger vehicles. CGA-PG12 - Do not open valve until connected to equipment prepared for use.
Other hazards which do not result in classification
Asphyxiant in high concentrations. 2.4.
Ingredient(s) with unknown acute toxicity