GHS02 GHS04 GHS07 GHS08
Health risk rating 5
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-59-7

Name of the chemical

Helium He

Concentration

24.9-84.6

EC/CAS

630-08-0

Name of the chemical

Kohlenmonoxid

Concentration

15.4-75.1

General Information

Revision date

2019-09-25

Product name

PTG-4075

Substance name

PTG-4075

1.2.1 Relevant identified uses

Calibration / Reference

Emergency telephone

Onsite Emergencies 1-800-645-4633; Australian

Icons in SDS

GHS02 GHS04 GHS07 GHS08 M004 M009 T017 T021

Company Information

company name

Scientific Gas Australia Pty Ltd

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H220, H280, H332, H360, H372

Hazard statements

Code

Statements

H220

Extremely flammable gas

Section 2

Classification (GHS-US)

Flam. Gas 1 H220 Press. Gas (Comp.) H280 Acute Tox. 4 (Inhalation:gas) H332 Repr. 1A H360 STOT RE 1 H372

2.2 Label elements

GHS AU labelling

Hazard pictograms

GHS02 GHS04 GHS07 GHS08

Signal word

GHS-AU) : DANGER

Hazard statements

H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H332 - HARMFUL IF INHALED H360 - MAY DAMAGE FERTILITY OR THE UNBORN CHILD H372 - CAUSES DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE

Precautionary statements

P271+P403 - Use and store only outdoors or in a well-ventilated place. P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P260 - Do not breathe gas/vapors P261 - Avoid breathing gas, vapors P264 - Wash exposed skin thoroughly after handling P270 - Do not eat, drink or smoke when using this product P280 - Wear protective gloves/protective clothing/eye protection/face protection P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. EN (English - AU) P308+P313 - If exposed or concerned: Get medical advice/attention P311 - Call a poison center/doctor/… P314 - Get medical advice/attention if you feel unwell P377 - LEAKING GAS FIRE: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P405 - Store locked up P410+P403 - Protect from sunlight. Store in a well-ventilated place. P501 - Dispose of contents/container in accordance with local/regional/national/international regulations. Contact supplier for any special requirements. CGA-PG27 - Read and follow the Safety Data Sheet (SDS) before use. CGA-PG21 - Open valve slowly. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F). CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG06 - Close valve after each use and when empty. CGA-PG10 - Use only with equipment rated for cylinder pressure. CGA-PG11 - Never put cylinders into unventilated areas of passenger vehicles. CGA-PG12 - Do not open valve until connected to equipment prepared for use.

Other hazards which do not result in classification

Asphyxiant in high concentrations. 2.4.

Ingredient(s) with unknown acute toxicity

No data available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.