LI-ION BATTERY PACK (SCL500RM1UC, SCL500RM1NC, SCL500RM1UNC, SCL400RMJ1U, SCL500RMI1U, SCL500RMI1UC, SCL500RMI1UNC)

Schneider Electric IT USA (formerly APC by Schneider Electric, APC Sales and Service

Revision date : 2020-08-03

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-44-0

Name of the chemical

Carbon black

Concentration

N/A

EC/CAS

7429-90-5

Name of the chemical

Aluminium

Concentration

N/A

EC/CAS

7440-50-8

Name of the chemical

Copper

Concentration

N/A

General Information

Revision date

2020-08-03

Product name

LI-ION BATTERY PACK (SCL500RM1UC, SCL500RM1NC, SCL500RM1UNC, SCL400RMJ1U, SCL500RMI1U, SCL500RMI1UC, SCL500RMI1UNC)

Product Synonyms

APC Smart-UPS Li-Ion, Short Depth 500VA, 120V and 230V with SmartConnect, APC

1.2.1 Relevant identified uses

Lithium-Ion battery pack APC by Schneider Electric Uninterruptible Power Supplies

Manufacturer Name

Schneider Electric IT USA (formerly APC by Schneider Electric, APC Sales and Service

Emergency telephone

For all Service, Technical Support and Emergency Inquires

Icons in SDS

Company Information

company name

Schneider Electric IT USA (formerly APC by Schneider Electric, APC Sales and Service

GHS Information

Signal word

No

Section 2

SECTION 2: Hazards identification

OSHA OSHA Hazard Communication Status: This material is not considered hazardous by the OSHA Hazard Communication Standard 29 CFR 1910.1200. Carcinogenicity (NTP): Not listed Carcinogenicity (IARC): Not listed Carcinogenicity (OSHA): Not listed

2.1 Classification of the substance or mixture

Not classified.

Signal word

No signal word.

Hazard statements

No known significant effects or critical hazards.

Prevention

Not applicable

Response

Not applicable

Storage

Not applicable

Disposal

Not applicable

2.3 Other hazards

Physical hazards not otherwise classified (PHNOC): None known. Health hazards not otherwise classified (HHNOC): In case of cell damage, possible release of dangerous substances and a flammable gas mixture.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.