Note: Ingredients listed on restricted chemical lists
EC/CAS
231-100-4/7439-92-1
Name of the chemical
Blei, massiv: [Partikeldurchmesser ≥ 1 mm]
Concentration
59.650%
Listed in
EC/CAS
231-639-5/7664-93-9
Name of the chemical
sulphuric acid
Concentration
18.150%
EC/CAS
9003-07-0
Name of the chemical
polypropylene wax
Concentration
10.000%
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
2.600%
EC/CAS
231-141-8/7440-31-5
Name of the chemical
Organometallic tin
Concentration
0.300% 27440-31- 0.100%
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
0.0036%
EC/CAS
7440-02-0
Name of the chemical
Nickel
Concentration
0.0020%
General Information
Version
1.1
Revision date
2020-03-15
Product name
Battery pack containing sealed lead acid batteries in an uninterruptible power supply
Product Synonyms
Battery pack or accumulator pack with Valve Regulated Lead Acid Battery- Wet, Non- Spillable
1.2.1 Relevant identified uses
Electric Storage Battery
Emergency telephone
800-255-3924, 1-813-248-0585
Icons in SDS
Company Information
company name
Schneider Electric IT USA
GHS Information
Signal word
DANGER
Hazard Codes
Hazard statements (CLP)
H302, H314, H360Df, H373, H400, H410
Hazard statements
Code
Statements
H302
Harmful if swallowed
H314
Causes severe skin burns and eye damage.
H360Df
May damage the unborn child. Suspected of damaging fertility.
H373
May cause damage to organs through prolonged or repeated exposure
H400
Very toxic to aquatic life
H410
Very toxic to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
Signal word
DANGER
Hazard statements
Battery pack containing sealed lead acid batteries (NA) 2 to 16
2.1 Classification of the substance or mixture
According to CLP No 1272/2008: Acute Toxicity Oral 4 – H302 Skin Corrosion 1A – H314 Reproductive Toxicity 1A – H360Df Specific Target Organ Toxicity Repeated Exposure 2 – H373 Hazardous to the aquatic environment Acute 1 – H400 Hazardous to the aquatic environment Chronic 1 – H410
Other hazards
D2A Corrosive – E
2.2 Label elements
Battery pack containing sealed lead acid batteries (NA) 3 to 16
2.3 Other hazards
In Canada, the product listed above is considered as hazardous according to the Workplace Hazardous
Further information
Acid batteries used in APC by Schneider Electric Replacement Battery Cartridges (RBCs) are contained within cartridges and are sealed, non-spillable design. Under normal use and handling, there is no contact with the internal components of the battery or the chemical hazards. Under normal use and handling, these products do not emit regulated or hazardous substances. Misuse of the product, such as overcharging, may result in a discharge of battery electrolyte. Classification provided are for the battery electrolyte and are only applicable in the event that the electrolyte is discharged.