Note: Ingredients listed on restricted chemical lists
EC/CAS
1304-28-5
Name of the chemical
Barium oxide, obtained by calcining witherite
Concentration
N/A
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
N/A
EC/CAS
1305-78-8
Name of the chemical
Calcium oxide
Concentration
N/A
EC/CAS
14464-46-1
Name of the chemical
Cristobalit (s. u. TRGS 906)
Concentration
N/A
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
N/A
General Information
Revision date
2020-04-15
Product name
Boundary Dam Fly Ash (CAS 68131-74-8)
CAS No.
68131-74-8
1.2.1 Relevant identified uses
This product is used primarily as a partial cement replacement in the production of ready-mixed
supplier name
SaskPower (Saskatchewan Power Corporation)
Manufacturer Name
SaskPower (Saskatchewan Power Corporation)
Icons in SDS
Company Information
company name
SaskPower (Saskatchewan Power Corporation)
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H314, H318, H335, H350, H372
Hazard statements
Code
Statements
H314
Causes severe skin burns and eye damage.
H318
Causes serious eye damage.
H335
May cause respiratory irritation
H350
May cause cancer
H372
Causes damage to organs through prolonged or repeated exposure
Section 2
WHMIS Classification
HHNOC 1 Skin Corr. 1A (see Note 1) H314 Eye Dam. 1 (see Note 1) H318 Carc. 1A (see Note 2) H350 STOT SE 3 H335 STOT RE 1 (see Note 3) H372 Note 1: The skin corrosion and eye damage hazard classifications are based on the high (basic, alkaline) pH obtained in a 20% suspension of fly ash in water. This may represent a very conservative (“worst case”) approach to classification of these hazards. No in vitro or in vivo data is available. Note 2: Fly ash, itself, is not a carcinogen. However, respirable crystalline silica in the form of quartz or cristobalite from occupational sources is is listed by ACGIH, IARC, and NTP as a lung carcinogen or suspected carcinogen. The fly ash contains crystalline silica; however, the respirable portion of the crystalline silica has not been determined. The level of risk associated with crystalline silica which occurs along with (i.e., attached to, embedded in) other material in a fly ash particle is not well understood, but may be reduced compared to inhalation of particles composed of “pure” crystalline silica. Note 3: Prolonged exposure to respirable crystalline silica may cause silicosis, a lung disease, which may be disabling. The fly ash contains crystalline silica; however, the respirable portion of the crystalline silica has not been determined.
2.2 Label elements
GHS-CA labelling
Signal word
Danger
Hazard statements
H314 - Causes severe skin burns and eye damage. H335 - May cause respiratory irritation. H350 - May cause cancer. H372 - Causes damage to organs through prolonged or repeated exposure.
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe dust. P264 - Wash hands, forearms and face thoroughly after handling. P270 - Do not eat, drink or smoke when using this product P271 - Use only outdoors or in a well-ventilated area. P280 - Wear protective gloves, protective clothing, eye protection. P308+P313 - IF exposed or concerned: Get medical advice/attention. P301+P330+P331 - IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P302+P335+P334 - IF ON SKIN: Brush off loose particles from skin. Immerse in cool water or wrap in wet bandages. 04/15/2020 P363 - Wash contaminated clothing before reuse. P304+P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. P312 - Call a POISON CENTER or doctor if you feel unwell. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 - Immediately call a POISON CENTER or doctor. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. P405 - Store locked up. P501 - Dispose of contents/container to hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Other hazards which do not result in classification
Note that, to some extent, irritation or burns may be thermal as well as caustic due to the heat released by the reaction of ash components (e.g, available alkalinity, such as calcium oxide or calcium hydroxide) with moisture (e.g, eyes, mucus membranes, sweat). Titanium dioxide is classified by IARC as a Group 2B carcinogen (possibly carcinogenic to humans). NIOSH considers ultrafine (respiratory particles with a primary particle diameter of < 100 nm) titanium dioxide as a potential occupational carcinogen, but considers there to be insufficient data to similarly classify fine titanium dioxide. Exposure to titanium dioxide dust may lead to other lung effects – e.g., fibrosis. The titanium content in fly ash is reported as TiO2; this the standard convention for the reporting of Ti content in fly ash: the actual occurence of any discrete particles of TiO2 in the fly ash is unknown. Although it is a transient rather than inherent characteristic of the fly ash, note that fly ash withdrawn directly from an electrostatic precipitator (ESP) hopper, fly ash storage (sales) silo, or encountered elsewhere in – or recently exited from – other power plant process equipment may be very hot due to retained heat originating from the coal combustion process. Consequent to the loading of hot fly ash from a silo, fly ash transport trailers may contain, transport, and subsequently deliver hot ash. Temperatures may be high enough to cause serious burns and to damage materials or equipment that come into contact with the ash. Additionally, the chemical reactivity of the hot fly ash – for example, the reaction of alkaline ash constituents with water – may be greatly enhanced relative to that of the ash at ambient temperatures, potentially generating additional heat, even higher temperatures, and – in the case of contact with water – flashing some of the water to steam. On request, SaskPower Coal Combustion Products will provide additional information by calling 1-800-667-8022 toll free (in Canada). 2.4.
Ingredient(s) with unknown acute toxicity
Not applicable