General Information
Revision date
2009-03-19
Product name
1-Hydroxytetraphenyl-cyclopentadienyl(tetraphenyl-2,4-cyclopentadien-1-one)-µ-hydrotetracarbonyldiruthenium(II)
CAS No.
104439-77-2
supplier name
Santa Cruz Biotechnology, Inc
Emergency telephone
+613 9573 3112
Icons in SDS
Company Information
company name
Santa Cruz Biotechnology, Inc
Section 2
SECTION 2: Hazards identification
CHEMWATCH HAZARD RATINGS Min Max Flammability 1 Toxicity 0 Min/Nil=0 Body Contact 0 Low=1 Moderate=2 Reactivity 1 High=3 Extreme=4 Chronic 0 CANADIAN WHMIS SYMBOLS None EMERGENCY OVERVIEW RISK
Potential Acute Health Effects
SWALLOWED ■ The material has NOT been classified by EC Directives or other classification systems as "harmful by ingestion". This is because of the lack of corroborating animal or human evidence. ■ Platinoids are poorly absorbed from the gut, skin and other routes not directly in the blood stream. More is absorbed if inhaled, and the substance is lodged in the lungs and airway. EYE ■ Although the material is not thought to be an irritant (as classified by EC Directives), direct contact with the eye may cause transient discomfort characterised by tearing or conjunctival redness (as with windburn). Slight abrasive damage may also result. SKIN ■ The material is not thought to produce adverse health effects or skin irritation following contact (as classified by EC Directives using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable gloves be used in an occupational setting. INHALED ■ The material is not thought to produce adverse health effects or irritation of the respiratory tract (as classified by EC Directives using animal models). Nevertheless, good hygiene practice requires that exposure be kept to a minimum and that suitable control measures be used in an occupational setting. ■ Persons with impaired respiratory function, airway diseases and conditions such as emphysema or chronic bronchitis, may incur further disability if excessive concentrations of particulate are inhaled. If prior damage to the circulatory or nervous systems has occurred or if kidney damage has been sustained, proper screenings should be conducted on individuals who may be exposed to further risk if handling and use of the material result in excessive exposures.
Potential chronic health
■ Long-term exposure to the product is not thought to produce chronic effects adverse to the health (as classified by EC Directives using animal models); nevertheless exposure by all routes should be minimised as a matter of course. Long term exposure to high dust concentrations may cause changes in lung function i.e. pneumoconiosis; caused by particles less than 0.5 micron penetrating and remaining in the lung. Prime symptom is breathlessness; lung shadows show on X-ray. Subcutaneous injection of cyclopentadiene into rabbits may cause unconsciousness, convulsion, motor unrest, and slow, irregular breathing prior to death. The liquid produced marked local irritation, fluid accumulation in the chest and abdomen, and increased blood flow to the kidneys. Exposure to dicyclopentadiene produced dose and duration dependent convulsions, kidney and liver damage, irreversible lung dilatation, bleeding in the lungs, intestines, and the thymus of female rats. Ruthenium is reported to possess anticancer and immunosuppressive properties but its ability to cause gene mutation is under review. However, its complexes exhibit positive reactions in the Ames test.