Note: Ingredients listed on restricted chemical lists
EC/CAS
235-008-5/7440-02-0
Name of the chemical
Nickel
Concentration
34% 8%
EC/CAS
244-168-5/7440-43-9
Name of the chemical
Cadmium
Concentration
1%
EC/CAS
244-166-4/7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
19%
EC/CAS
215-181-3/1310-58-3
Name of the chemical
potassium hydroxide
Concentration
1% 24% 4%
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
N/A
General Information
Revision date
2017-09-14
Product name
Industrial Ni-Cd cells and battery systems composed of these cells
supplier name
Headquarters
Manufacturer Name
Saft Bordeaux
Emergency telephone
+800 424 93 00, +1-202-483-7616, +33(0) 1 45 42 59 59
Icons in SDS
Company Information
company name
Saft AB
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H314, H402
Hazard statements
Code
Statements
H301
Toxic if swallowed
Section 2
SECTION 2: Hazards identification
GHS Classification 2.1 Electrolyte contained in individual cells
Signal word
Danger Electrolyte Hazard statements: H301 Toxic if swallowed. H314 Causes severe skin burns and eye damage. H402 Harmful to aquatic life.
Health hazards
Corrosive. Causes burns to the respiratory tract, skin, eyes, and gastro- intestinal tract. CAUSES PERMANENT EYE DAMAGE. Effects of contact or inhalation MAY BE DELAYED.
Physical hazards
Mixing with water, acid or incompatible material may cause splattering and release of heat. Do not store in aluminum or use aluminum fittings or transfer lines as flammable hydrogen may be generated. Ecological Hazards: This material is toxic to aquatic organisms. 2.2 At cell level Not chemically dangerous under normal conditions of use where the electrode materials and the electrolyte are enclosed within the cell. The battery should not be opened or burned. Exposure to or ingestion of the ingredients contained within the cell could be harmful. The following information regarding the hazardous constituents contained within the battery is provided for the user’s information: EYE CONTACT: Contact with the electrolyte (potassium hydroxide solution) inside the cells can cause severe eye damage. SKIN CONTACT: Contact with the electrolyte contained inside cells can cause severe burns. CARCINOGENIC COMPONENTS: Cadmium and Nickel compounds 2.3 At module and battery system level HIGH VOLTAGE: Always use the large battery systems in a restricted access area. Only authorized people aware of high voltage hazards and trained to work on such systems are allowed to enter in the battery area. TEMPERATURE: Do not place the batteries on or near fires or other high-temperature locations (> 70°C).