Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-49-0
Name of the chemical
Naphtha (petroleum), hydrotreated light; Low boiling point hydrogen treated naphtha (A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C4 through C11 and boiling in the range of approximately - 20 °C to 190 °C.)
Concentration
10-25
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
2.5-10
EC/CAS
14807-96-6
Name of the chemical
Talc
Concentration
2.5-10
EC/CAS
96-29-7
Name of the chemical
2-Butanonoxim (2020/1182)
Concentration
0.1-1.0 51-373-
EC/CAS
7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
0.1-1.0
EC/CAS
64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy; Low boiling point hydrogen treated naphtha (A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C6 through C13 and boiling in the range of approximately 65 °C to 230 °C.)
Concentration
0.1-1.0
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
0.1-1.0
General Information
Revision date
2024-02-23
Product name
ZINSSR 3.78L 4PK IBU COVERSTAIN Revision Date: 23/02/2024 PRIMER
Product name
ZINSSR 3.78L 4PK IBU COVERSTAIN Revision Date: 23/02/2024 PRIMER
Identification on the label/Trade name
Cover Stain Undercoat Primer-Sealer Stain Supercedes Date: 22/01/2024 Blocker
1.2.1 Relevant identified uses
Coverstain/Alkyd
supplier name
Rust-Oleum New Zealand
Manufacturer Name
Rust-Oleum Corporation
Icons in SDS
Company Information
company name
Rust-Oleum Corporation
e-mail address of the competent person responsible for the Safety Data Sheet
technical@rustoleum.co.nz
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H226, H317, H351, H361, H412
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
H317
May cause an allergic skin reaction
H351
Suspected of causing cancer
H361
Suspected of damaging fertility or the unborn child
H412
Harmful to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Symbol(s) of Product
Signal word
23% of the mixture consists of ingredient(s) of unknown acute toxicity.
Hazard statements
Carcinogenicity, category 2 Flammable Liquid, category 3 H351 Suspected of causing cancer. H226 Flammable liquid and vapour. Hazardous to the Aquatic Environment, H412 Harmful to aquatic life with long lasting effects. Chronic, category 3 Reproductive Toxicity, category 2 Skin Sensitizer, category 1 H361 Suspected of damaging fertility or the unborn child. H317 May cause an allergic skin reaction.
Precautionary statements
P201 Obtain special instructions before use. P203 Obtain, read, and follow all safety instructions before use. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P272 Contaminated work clothing should not be allowed out of the workplace. P273 Avoid release to the environment. P280 Wear protective gloves / protective clothing / eye protection / face protection. P302+P352 IF ON SKIN: Wash with plenty of soap and water. P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P308+P313 IF exposed or concerned: Get medical advice/attention. P308+P316 IF exposed or concerned: Get emergency medical help immediately. P321 Specific treatment (see notice on this label). P333+P317 If skin irritation or rash occurs: Get medical help. P362+P364 Take off contaminated clothing and wash it before reuse. P370+P378 In case of fire: Extinguish using suitable extinguishing media. P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P501 Dispose of contents and container in accordance with local, regional and national regulations. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof electrical, ventilating, lighting, or pouring equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges.