Note: Ingredients listed on restricted chemical lists
EC/CAS
9016-87-9
Name of the chemical
4,4'-Methylendiphenyldiisocyanat tech. (Polymeres) MDI, pMDI (in Form atembarer Aerosole, A-Fraktion)
Concentration
N/A
EC/CAS
101-68-8
Name of the chemical
4,4’-Methylenediphenyl diisocyanate
Concentration
N/A
EC/CAS
5873-54-1
Name of the chemical
2,4’-Methylenediphenyl diisocyanate
Concentration
N/A
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
N/A
General Information
Revision date
2019-11-01
Product name
AEROSOLS
1.2.1 Relevant identified uses
Cavity sealing foam
Emergency telephone
CHEMWATCH EMERGENCY RESPONSE
Icons in SDS
Company Information
company name
RS Components
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H315, H317, H319, H334, H335, H351, H373
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. CHEMWATCH HAZARD RATINGS Min Max Flammability 4 Toxicity 0 0 = Minimum Body Contact 2 1 = Low 2 = Moderate Reactivity 1 3 = High Chronic 2 4 = Extreme Poisons Schedule Not Applicable Flammable Aerosols Category 1, Skin Corrosion/Irritation Category 2, Eye Irritation Category 2A, Skin Sensitizer Category 1, Respiratory [1] Sensitizer Category 1, Carcinogenicity Category 2, Specific target organ toxicity - single exposure Category 3 (respiratory tract irritation), Specific target organ toxicity - repeated exposure Category 2 Legend: 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI
Signal word
DANGER
Hazard statements
H222 Extremely flammable aerosol. H315 Causes skin irritation. H319 Causes serious eye irritation. H317 May cause an allergic skin reaction. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H351 Suspected of causing cancer. H335 May cause respiratory irritation. H373 May cause damage to organs through prolonged or repeated exposure. AUH044 Risk of explosion if heated under confinement.
Prevention
P201 Obtain special instructions before use. P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use.
Response
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P308+P313 IF exposed or concerned: Get medical advice/attention. P321 Specific treatment (see advice on this label). P342+P311 If experiencing respiratory symptoms: Call a POISON CENTER or doctor/physician.
Storage
P405 Store locked up. P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F. P403+P233 Store in a well-ventilated place. Keep container tightly closed.
Disposal
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.