Note: Ingredients listed on restricted chemical lists
EC/CAS
85535-85-9
Name of the chemical
Alkanes, C14-17, chloro
Concentration
50-<80 14-17
EC/CAS
94266-48-5
Name of the chemical
Pinus species oil and extract
Concentration
<1
General Information
Version
8.1
Revision date
2021-04-15
Product name
Rocol RTD Compound
Product name
Rocol RTD Compound
Identification on the label/Trade name
52, 58% and pine oil, concrete
Product Synonyms
Not Available
Chemical name
Not Applicable
1.2.1 Relevant identified uses
Industrial and commercial application ,metalworking adjuvant ,lubricant
Emergency telephone
+44 (0) 113 232 2600, +61 1800 951 288, +61 3 9573 3188
Icons in SDS
Company Information
company name
Rocol
e-mail address of the competent person responsible for the Safety Data Sheet
customer-service@rocol.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H362, H402, H410
Hazard statements
Code
Statements
H362
May cause harm to breast-fed children
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Poisons Schedule Not Applicable [1] Reproductive Toxicity Effects on or via Lactation, Hazardous to the Aquatic Environment Acute Hazard Category 3, Hazardous to the Aquatic Environment Long-Term Hazard Category 1 Legend 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from
Hazard pictograms
Page 1 continued...
Signal word
Warning
Hazard statements
H362 May cause harm to breast-fed children. H402 Harmful to aquatic life. H410 Very toxic to aquatic life with long lasting effects. AUH066 Repeated exposure may cause skin dryness and cracking.
Prevention
P201 Obtain special instructions before use. P260 Do not breathe dust/fume. P263 Avoid contact during pregnancy and while nursing. P270 Do not eat, drink or smoke when using this product. P273 Avoid release to the environment. P264 Wash all exposed external body areas thoroughly after handling.
Response
P308+P313 IF exposed or concerned: Get medical advice/ attention. P391 Collect spillage.
Storage
Not Applicable
Disposal
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation. Not Applicable