MAC-Guard R-Component

Res-Tek, Inc

Revision date : 2016-01-26

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS07 GHS08 GHS02
Health risk rating 5
Safety risk rating 3
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

101-68-8

Name of the chemical

4,4’-Methylenediphenyl diisocyanate

Concentration

50-70 10-25

EC/CAS

80-62-6

Name of the chemical

methacrylic acid, methyl ester

Concentration

30-50 <4

General Information

Revision date

2016-01-26

Product name

MAC-Guard R-Component

Chemical name

Mixture

1.2.1 Relevant identified uses

Additive for Industrial Flooring Resin

Emergency telephone

1-800-424-9300 / 1, (703) 527-3887

Icons in SDS

E003 GHS02 GHS07 GHS08 M004 M009 M011 M013 M017

Company Information

company name

Res-Tek, Inc

GHS Information

Signal word

DANGER

Hazard Codes

Hazard statements (CLP)

H225, H315, H317, H319, H332, H334, H335, H373

Hazard statements

Code

Statements

H225

Highly Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

(29 CFR 1910.1200) Classification of the substance or mixture

Signal word

DANGER

Hazard statements

Highly flammable liquid and vapor. Harmful if inhaled. Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. May cause allergy or asthma symptoms or breathing difficulties if inhaled. May cause respiratory irritation. May cause damage to organs through prolonged or repeated exposure: Inhalation, respiratory system.

Precautionary statements

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharge. Ground/bond container and receiving equipment. Use only non-sparking tools. Use explosion-proof electrical/ventilating/lighting/equipment. Keep container tightly closed. Wear protective gloves/eye protection/face protection. Do not breathe dust/fume/gas/mist/vapours/spray. Wash hands and exposed skin after use. Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace.

2.3 Other hazards

Harmful to aquatic life. Harmful to aquatic life with long lasting effects.

Additional information

None

2.1 Classification of the substance or mixture

OSHA HCS (29 CFR 1910.1200) Flam. Liq. 2; Acute Tox. 4; Skin Irrit. 2; Eye Irrit. 2; Skin Sens. 1; Resp. Sens. 1; STOT SE 3; STOT RE 1

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.