Note: Ingredients listed on restricted chemical lists
EC/CAS
265-151-9/64742-49-0
Name of the chemical
Naphtha (petroleum), hydrotreated light
Concentration
60-<65%
EC/CAS
205-500-4/141-78-6
Name of the chemical
acetic acid, ethyl ester
Concentration
10-<15%
General Information
Revision date
2017-07-05
Product name
180.000 Renia - Gummiloesung - Rubber Solution
Icons in SDS
Company Information
company name
Renia Gesellschaft mbH
e-mail address of the competent person responsible for the Safety Data Sheet
info@renia.com, labor@renia.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H319, H411
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Regulation (EC) No. 1272/2008
Hazard categories
Flammable liquid: Flam. Liq. 2 Skin corrosion/irritation: Skin Irrit. 2 Serious eye damage/eye irritation: Eye Irrit. 2 Hazardous to the aquatic environment: Aquatic Chronic 2
Hazard statements
Highly flammable liquid and vapour. Causes skin irritation. Causes serious eye irritation. Toxic to aquatic life with long lasting effects. H225 Highly flammable liquid and vapour. H315 Causes skin irritation. H319 Causes serious eye irritation. H411 Toxic to aquatic life with long lasting effects.
2.2 Label elements
Regulation (EC) No. 1272/2008
Hazardous Ingredients
Ethyl acetate Naphtha (petroleum), hydrotreated light; Low boiling point hydrogen treated naphtha xylene
Signal word
Danger
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P261 Avoid breathing dust/fume/gas/mist/vapours/spray. P264 Wash hands thoroughly after handling. P403+P235 Store in a well-ventilated place. Keep cool.
Special rules for supplemental label elements for certain mixtures
EUH066 Repeated exposure may cause skin dryness or cracking. EUH208 Contains natural rubber. May produce an allergic reaction.
Supplemental label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP]
2.3 Other hazards
In case of insufficient ventilation and/or through use, explosive/highly flammable mixtures may develop.