General Information
Revision date
2019-11-02
Product name
HydroFlame Smoke and Acoustic
Chemical name
Organic/Inorganic
1.2.1 Relevant identified uses
Firestopping Material
Manufacturer Name
Reliance Worldwide Corporation (RWC)
Emergency telephone
(800)-424-9300, (703)-527-3887
Icons in SDS
Company Information
company name
Reliance Worldwide Corporation (RWC)
Section 2
SECTION 2: Hazards identification
Classification According to Directive 67/548/EEC or 1999/45/EC: GHS CLASSIFICATION
Physical hazards
None
Health hazards
Acute Toxicity Oral: Not Classified Dermal: Not Classified Inhalation: Not Classified Skin Corrosion/Irritation: Not Classified Serious Eye Damage/Eye Irritation: Not Classified Respiratory or Skin Sensitization: Not Classified Germ Cell Mutagenicity: Not Classified Carcinogenicity: Not Classified Reproductive Toxicology: Not Classified Target Organ Systemic Toxicity - Single Exposure: Not Classified Target Organ Systemic Toxicity - Repeated Exposure: Not Classified Aspiration Toxicity: Not Classified
Environmental hazards
Hazardous to the Aquatic Environment: Not Classified Acute aquatic toxicity: Not Classified Chronic aquatic toxicity: Not Classified Bioaccumulation potential: Not Classified Rapid degradability: Not Classified GHS Label elements, including precautionary statements Pictogram: None Signal Word: None Hazard Statements None Precautionary Statements P102 - Keep out of reach of children P264 - Wash hands thoroughly after handling
2.2 Label elements
Symbols None
Hazard statements
None Safety S-Phrases: S2: Keep out of the reach of children. Summary of Acute Hazards May cause skin irritation. Route of Exposure, Signs and Symptoms INHALATION Not a respiratory irritant. EYE CONTACT Contact may cause eye irritation. SKIN CONTACT Contact may cause skin irritation. INGESTION Possible irritation to mucous membranes of the mouth, throat, and stomach. SUMMARY OF CHRONIC HAZARDS None known.
Medical Conditions Generally Aggravated by Exposure
Persons with pre-existing skin conditions or chemical allergies may be more susceptible to contact effects of the cured elastomer.
2.1 Classification of the substance or mixture
Physical Hazards: None Health Hazards Acute Toxicity: Oral: Not Classified Dermal: Not Classified Inhalation: Not Classified Skin Corrosion/Irritation: Not Classified Serious Eye Damage/Eye Irritation: Not Classified Respiratory or Skin Sensitization: Not Classified Germ Cell Mutagenicity: Not Classified Carcinogenicity: Not Classified Reproductive Toxicology: Not Classified Target Organ Systemic Toxicity - Single Exposure: Not Classified Target Organ Systemic Toxicity - Repeated Exposure: Not Classified Aspiration Toxicity: Not Classified 1 ENVIRONMENTAL HAZARDS Hazardous to the Aquatic Environment: Not Classified Acute aquatic toxicity: Not Classified Chronic aquatic toxicity: Not Classified Bioaccumulation potential: Not Classified Rapid degradability: Not Classified GHS Label elements, including precautionary statements Pictogram: None Signal Word: None Hazard Statements: None Precautionary Statements: P102 - Keep out of reach of children. P264 - Wash hands thoroughly after handling. Classification according to EU Directives 67/548/EEC or 1999/45/EC Labeling Symbols: None Risk R-Phrases: None Safety S-Phrases: S2: Keep out of the reach of children. Summary of Acute Hazards May cause skin irritation. Route of Exposure, Signs and Symptoms INHALATION Not a respiratory irritant. EYE CONTACT Contact may cause eye irritation. SKIN CONTACT Contact may cause skin irritation. INGESTION Possible irritation to mucous membranes of the mouth, throat, and stomach. SUMMARY OF CHRONIC HAZARDS None known. MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE Persons with pre-existing skin conditions or chemical allergies may be more susceptible to contact effects of the cured elastomer. Section 3 – Composition/Information on Ingredients % by WT CAS No. INGREDIENT UNITS None as defined by OSHA Hazard Communication Standard 29 CFR 1910.1200. 2 Section 4 – First Aid Measures If inhaled: Not a respiratory irritant. If on skin: Wash with soap and water. If irritation occurs, seek medical attention. If in eyes: Immediately flush with large amounts of water. If irritation occurs, seek medical attention. If swallowed: If swallowed, call a physician immediately. Only induce vomiting at the instruction of a physician. Never give anything by mouth to an unconscious person. Section 5 – Fire Fighting Measures Flash Point LEL UEL None N/D Extinguishing Media Foam, dry chemical, carbon dioxide or water fog. Special Fire Fighting Procedures: Wear self-contained breathing apparatus (SCBA) and other protective clothing. Hazardous decomposition products possible (see Section 10) Unusual Fire and Explosion Hazards: Fire conditions will activate product causing intumescence to occur. Section 6 -Accidental Release Measures Steps to Be Taken in Case Material Is Released or Spilled: Wipe us spills to prevent footing hazard. Avoid flushing into sewers, drains, waterways and soil. Wear protective clothing during clean up. Section 7 – Handling and Storage Precautions to Be Taken in Handling and Storing: Keep container closed and upright when not in use. To prevent freezing and possible rupture of container, do not store below 35 F. Other Precautions: Avoid prolonged or repeated contact with skin or clothing. Empty containers may contain residues and vapors; treat as if full and observe all product precautions. Do not reuse empty containers. KEEP OUT OF REACH OF CHILDREN. 3 Section 8 – Exposure Controls/Personal Protection Respiratory Protection (Specify Type): None required. Ventilation − Local Exhaust: Acceptable Special: N/A Mechanical (General): Preferable Other: N/A Protective Gloves: Wear rubber gloves. Eye Protection: Safety glasses (ANSI Z-87.1 or equivalent) Other Protective Clothing or Equipment: Coveralls recommended. Work/Hygienic Practices: Where sue can result in skin contact, wash exposed areas thoroughly before eating, drinking, smoking or leaving work area. Launder contaminated clothing before reuse. Section 9 – Physical and Chemical Properties Boiling point: 212 F (100C) @ 760mm HG Specific gravity (H20 = 1): 1.1 Vapor pressure (mmHg): 17 @ 68 F (20 C) Melting point: N/A Vapor Density (Air = 1): N/A Evaporation rate (Ethyl Acetate = 1): >1 Appearance/Odor: Beige/Mild odor Solubility in water: Soluble Volatile Organic Compounds (VOC) Content (theoretical percentage by weight): < 1% or (< 10 g/L) Flash point: None Lower explosion limit: None Upper explosion limit: None Section 10 – Stability and Reactivity Stability: Stable Conditions to Avoid: None. Incompatibility (Materials to Avoid): None known. Hazardous Decomposition Products: CO, CO2 and fragmented hydrocarbons. Hazardous Polymerization: Will not occur. 4 Section 11 – Toxicology Information Chronic Health Hazards No ingredient in this product is an IARC, NTP or OSHA Lister carcinogen. Toxicology Data Ingredient Name None Section 12 - Ecological Information Ecological Data Ingredient Name: None Food Chain Concentration Potential: N/A Waterfowl Toxicity: N/A BOD: N/A Aquatic Toxicity: N/A Section 13 – Disposal Considerations Waste Classification: Non-regulated solid waste Disposal Method: Approved landfill Waste from this product is not considered hazardous as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Dispose of in accordance with federal, state, and local regulation regarding pollution. Section 14 – Transportation Information DOT: Non-regulated Ocean (IMDG): Non-regulated Air (IATA): Non-regulated WHMIS (Canada): Non-regulated 5 Section 15 – Regulatory Information Regulatory Data Ingredient Name: None SARA 313 N/A TSCA Inventory All components listed CERCLA RQ N/A RCRA Code N/A Section 16 -Other Information This document is prepared pursuant to the OSHA Hazard Communication Standard (29 CFR 1910.1200). The information herein is given in good faith, but no warranty, expressed or implied is made. Consult Reliance Worldwide Corporation (RWC) for further information: (877) 700-4242 6 3/14/2019 Holdrite Microbiological Analysis Report Project No: 14118-A Date Received: 2/11/2019 Date of Analysis: 2/11/2019 Subject: Fungal Resistance Testing Background & Objectives Five samples were received for fungal resistance testing using the ASTM G21 test method. Protocol ASTM G21-15, Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi, test was strictly followed. Overview of Test Protocol This test method is designed for the qualitative determination of mildew (fungus) resistance of synthetic polymeric materials, particularly those types which have been given a fungus resistant treatment. Specifics of the Test Lab ID Sample ID 14118-A HydroFlame™ 50 Test Inoculum The fungal inoculum consisted of five species: Aspergillus brasiliensis ATCC 9642 Chaetomium globosum ATCC 6205 Penicillium funiculosum ATCC 11797 Trichoderma virens ATCC 9645 Aureobasidium pullulans ATCC 15233 Test samples were placed in petri dishes on nutrient salts agar and inoculated with the test fungi. The samples were incubated at 28°C for 4 weeks and examined weekly for the growth of the test organisms. 1950 Tobsal Court •Warren, MI 48091-1351 USA Phone: 586.755.8970 •Toll-Free: 800.253.6800 •Fax: 586.755.8978 www.biosan.com 1 of 4 3/14/2019 Holdrite Microbiological Analysis Report Project No: 14118-A Evaluation of Results For the evaluation of the relative resistance of synthetic polymeric materials, the following rating system was used: Fungal Growth Rating Legend None 0 Traces of growth (less than 10%) 1 Light growth (10-30%) 2 Medium growth (30-60%) 3 Heavy growth (60% to complete coverage) 4 Results Table 1 shows the Fungal Resistance Test results. Conclusions The Holdrite sample HydroFlame™ 50 showed fungal resistance after four weeks in the ASTM G21 test. No growth was observed on the samples. There were little depressions formation on the sample with the inoculum droplets. Geetanjli Sharma Microbiologist Silveria Cristo Microbiologist 1950 Tobsal Court •Warren, MI 48091-1351 USA Phone: 586.755.8970 •Toll-Free: 800.253.6800 •Fax: 586.755.8978 www.biosan.com 2 of 4 3/14/2019 Holdrite Microbiological Analysis Report - ASTM G21-15 Project No: 14118-A Table 1. Fungal Resistance of Polymeric Surfaces Observed Fungal Growth on Treated Lab Surface after 28 days Incubation at Sample 28-30°C Identification 1 2 3 14118-A HydroFlame™ 50 0 PC Growth Control (Whatman filter paper) 4 Fungal Growth Rating Legend None 0 Traces of growth (less than 10%) 1 Light growth (10-30%) 2 Medium growth (30-60%) 3 Heavy growth (60% to complete coverage) 4 1950 Tobsal Court •Warren, MI 48091-1351 USA Phone: 586.755.8970 •Toll-Free: 800.253.6800 •Fax: 586.755.8978 www.biosan.com 3 of 4 3/14/2019 Holdrite Microbiological Analysis Report - ASTM G21-15 Project No: 14118-A Photos after 4 weeks of testing: 14118-A Whatman Filter Paper 1950 Tobsal Court •Warren, MI 48091-1351 USA Phone: 586.755.8970 •Toll-Free: 800.253.6800 •Fax: 586.755.8978 www.biosan.com 4 of 4