Note: Ingredients listed on restricted chemical lists
EC/CAS
309-877-7/101316-72-7
Name of the chemical
Lubricating oils (petroleum), C24-50, solvent-extd., dewaxed, hydrogenated
Concentration
1-3
EC/CAS
265-156-6/64742-53-6
Name of the chemical
Distillates (petroleum), hydrotreated light naphthenic
Concentration
0,3-0
EC/CAS
265-157-1/64742-54-7
Name of the chemical
Distillates (petroleum), hydrotreated heavy paraffinic
Concentration
80-90
EC/CAS
207-439-9
Name of the chemical
Calcium carbonate
Concentration
0,3-0
General Information
Revision date
2020-10-21
Product name
Eni i-Sint 0W-20
Emergency telephone
CNIT +39 0382 24444 (24h) (IT + EN
Icons in SDS
Company Information
company name
Refining & Marketing
e-mail address of the competent person responsible for the Safety Data Sheet
SDSInfo@eni.com
Section 2
SECTION 2: Hazards identification
According to Regulation (EC) No. 1272/2008 (CLP)]
CLP CLASSIFICATION
EU-GHS / CLP]Mixtures/Substances SDS EU 2015 According to Regulation (EU) 2015/830 (REACH Annex II) Not classified
Adverse physicochemical, human health and environmental effects
Prolonged and repeated skin contact may cause reddening, irritation and dermatitis. May produce an allergic reaction. For specific information about the toxicological/ecotoxicological properties and classification of this product, see Sect. 11 and/or Sect. 12.
2.2 Label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP] Extra labelling to displayExtra classification(s) to display
Supplemental label elements
EUH208 - Contains Dihydro-3-(tetrapropenyl)furan-2,5-dione. May produce an allergic reaction. EUH210 - Safety data sheet available on request. Other hazards (not relevant for classification)
Other hazards which do not result in classification
This product is combustible, but not classified as Flammable. The creation of flammable vapour mixtures takes place at temperatures which are higher than normal ambient levels. In case of contact with eyes, this product may cause irritation. Any substance, in case of accidents involving pressurized circuits and the like, may be accidentally injected under the skin, even without external damage. In such a case, the victim should be brought to an hospital as soon as possible, to get specialized medical treatment. Do not wait for symptoms to develop. A potential risk may arise from the release of hydrogen sulfide, when the product is stored or handled at high temperature. Hydrogen sulphide can react with iron oxide (rust) on the walls and ceilings of tanks to form pyrophoric iron sulphide, a known ignition source in the presence of oxygen. This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII