Note: Ingredients listed on restricted chemical lists
EC/CAS
204-881-4/128-37-0
Name of the chemical
2,6-di-tert-butyl-p-cresol
Concentration
<0.0005
General Information
Revision date
2020-04-01
Product name
DIETHYL ETHER
CAS No.
60-29-7
Emergency telephone
(662) 613-7911-4
Icons in SDS
Company Information
company name
RCI LABSCAN LIMITED
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H224, H302, H336
Hazard statements
Code
Statements
H224
Extremely flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flammable liquids (Category 1), H224 Acute toxicity, oral (Category 4), H302 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336 For the full text of the H-Statements mentioned in this Section, see Section 16.
2.2 Label elements
Labelling according Regulation (EC) No 1272/2008
Signal word
Danger
Hazard statements
H224 Extremely flammable liquid and vapour. H302 Harmful if swallowed. H336 May cause drowsiness or dizziness. EUH019 May form explosive peroxides. EUH066 Repeated exposure may cause skin dryness or cracking.
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof [electrical/ventilating/lighting] equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P261 Avoid breathing vapours. P264 Wash hand thoroughly after handling. P270 Do not eat, drink or smoke when using this product. P271 Use only outdoors or in a well-ventilated area. P280 Wear protective gloves/protective clothing/eye protection/face protection. P301 + P312 IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P330 Rinse mouth. P370 + P378 In case of fire: Use carbon dioxide, dry chemical or foam to extinguish. P403 + P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.
2.3 Other hazards
None