Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-65-0
Name of the chemical
Distillates (petroleum), solvent-dewaxed heavy paraffinic
Concentration
≥75
EC/CAS
64742-54-7
Name of the chemical
Distillates (petroleum), hydrotreated heavy paraffinic
Concentration
0 - 10
EC/CAS
64742-55-8
Name of the chemical
Distillates (petroleum), hydrotreated light paraffinic
Concentration
0 - 10
General Information
Version
3.0
Revision date
2023-06-07
Product name
XCELTHERM HFF
1.2.1 Relevant identified uses
High flash point of greater than 460°F (238°C) as measured by Cleveland Open Cup method (ASTM D92), petroleum based, non-toxic for use up to 315°C (600°F)
supplier name
Radco Industries Inc
Manufacturer Name
Radco Industries Inc
Emergency telephone
1-800-424-9300, +1 703-741-5970
Icons in SDS
Company Information
company name
Radco Industries Inc
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H332
Hazard statements
Code
Statements
H332
Harmful if inhaled
Section 2
SECTION 2: Hazards identification
Classification (GHS-US)
Acute toxicity (inhalation:dust,mist) Category 4 H332 Harmful if inhaled
Hazard statements
see section 16 H332 - Harmful if inhaled
2.2 Label elements
7/6/2023 (Revision date) US - en GHS US labeling
Signal word
Warning
Precautionary statements
P261 - Avoid breathing fume, mist, spray, vapors. P271 - Use only outdoors or in a well-ventilated area. P304+P340 - If inhaled: Remove person to fresh air and keep comfortable for breathing. P312 - Call a doctor, a POISON CENTER if you feel unwell.
Other hazards which do not result in classification
No additional information available
Ingredient(s) with unknown acute toxicity
Not applicable