Note: Ingredients listed on restricted chemical lists
EC/CAS
231-147-0/7440-37-1
Name of the chemical
Argon Ar
Concentration
90%
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
10%
General Information
Revision date
2022-05-30
Product name
Argon, Carbon Dioxide
Product Synonyms
ARGON 010, ARGON MIX
Chemical name
Argon 90%, Carbon Dioxide 10%
1.2.1 Relevant identified uses
Shielding Gas for Welding; Industrial
supplier name
Puregas Aust Pty Ltd
Icons in SDS
Company Information
company name
Puregas Aust Pty Ltd
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Gases Under Pressure Compressed Gas Dilute spill and run off.
2.2 Label elements
E — Evacuation of people in and around the immediate vicinity of the incident should be WARNING considered. Signal Word SECTION 6 ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures. Non-emergency personnel: No action shall be taken involving any personal
Hazard pictograms
risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and
Hazard statements
H280 - Contains gas under pressure; May explode if heated unprotected personnel from entering. Avoid breathing gas. Provide adequate ventilation. If the cylinder is leaking, evacuate area of P410 +P403 Protect from sunlight. Store in a Environmental
Prevention
None allocated personnel. Inform manufacturer/supplier of leak.
Response
None allocated Storage
Precautionary statements
well-ventilated place Use Personal Protective Equipment (PPE) as detailed in Section 8 of the SDS. Prevent from entering sewers, basements and work pits, or any place where its accumulation can be dangerous.
Disposal
None allocated Methods of cleaning up
Other hazards
Asphyxiant. In addition to any other important health or physical hazards, this product may displace oxygen and cause rapid suffocation. Reference to other sections Carefully move to a well-ventilated area. Allow gas to escape to atmosphere, preferably in an open remote location. Do not attempt to repair leaking valve or cylinder safety devices. See Section 8 for Exposure Controls and Section 13 for disposal considerations