Note: Ingredients listed on restricted chemical lists
EC/CAS
101-68-8
Name of the chemical
4,4’-Methylenediphenyl diisocyanate
Concentration
N/A
EC/CAS
9016-87-9
Name of the chemical
4,4'-Methylendiphenyldiisocyanat tech. (Polymeres) MDI, pMDI (in Form atembarer Aerosole, A-Fraktion)
Concentration
N/A
EC/CAS
26447-40-5
Name of the chemical
Methylenediphenyl diisocyanate (see also specific isomers)
Concentration
N/A
General Information
Revision date
2018-11-01
Product name
2600UR-TL
1.2.2. Uses advised against
No additional information available
supplier name
Protective Industrial Polymers
Icons in SDS
Company Information
company name
Protective Industrial Polymers
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H317, H334, H351, H373
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
Classification (GHS-US)
Flammable liquids H226 Flammable liquid and vapor Category 3 Respiratory sensitisation H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled Category 1 Skin sensitization Category H317 May cause an allergic skin reaction 1 Carcinogenicity Category 2 H351 Suspected of causing cancer Specific target organ H373 May cause damage to organs through prolonged or repeated exposure toxicity (repeated exposure) Category 2
Hazard statements
see section 16 : H226 - Flammable liquid and vapor H317 - May cause an allergic skin reaction H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled H351 - Suspected of causing cancer H373 - May cause damage to organs through prolonged or repeated exposure
2.2 Label elements
GHS-US labeling
Signal word
Danger
Precautionary statements
P201 - Obtain special instructions before use P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from sparks. - No smoking P233 - Keep container tightly closed P240 - Ground/Bond container and receiving equipment P241 - Use explosion-proof electrical equipment P242 - Use only non-sparking tools P243 - Take precautionary measures against static discharge P260 - Do not breathe vapours P261 - Avoid breathing vapors P272 - Contaminated work clothing must not be allowed out of the workplace P280 - Wear protective clothing P284 - [In case of inadequate ventilation] wear respiratory protection 11/01/2018 EN (English US) P302+P352 - If on skin: Wash with plenty of soap P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower P304+P341 - If inhaled: If breathing is difficult, remove person to fresh air and keep comfortable for breathing P308+P313 - If exposed or concerned: Get medical advice/attention P314 - Get medical advice/attention if you feel unwell P321 - Specific treatment (see a doctor if symptoms do not go away. on this label) P333+P313 - If skin irritation or rash occurs: Get medical advice/attention P342+P311 - If experiencing respiratory symptoms: Call a doctor P363 - Wash contaminated clothing before reuse P370+P378 - In case of fire: Use to extinguish P403+P235 - Store in a well-ventilated place. Keep cool P405 - Store locked up P501 - Dispose of contents/container to in accordance with local regulations
Other hazards which do not result in classification
No additional information available 2.4.
Ingredient(s) with unknown acute toxicity
Not applicable