ETHYL METHACRYLATE - EMA

PROQUIGEL QUÍMICA S/A

Revision date : 2021-03-29

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS02 GHS07
Health risk rating 4
Safety risk rating 3
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

97-63-2

Name of the chemical

methacrylic acid, ethyl ester

Concentration

100%

General Information

Revision date

2021-03-29

Product name

ETHYL METHACRYLATE - EMA

CAS No.

97-63-2

Emergency telephone

0800 110 8270 Pró-Química

Icons in SDS

GHS02 GHS07

Company Information

company name

PROQUIGEL QUÍMICA S/A

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H225, H315, H317, H319, H335, H402

Hazard statements

Code

Statements

H225

Highly Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

Flammable liquids – Category 2 Skin corrosion/irritation – Category 2

2.1 Classification of the substance or mixture

Eye damage/irritation – Category 2A Sensitization – skin – Category 1 Specific target organ toxicity – single exposure – Category 3 Hazardous to the aquatic environment – Acute – Category 3 Globally Harmonized System of Classification and Labelling of

Classification system

adopted Chemicals (GHS), United Nations, 2019.

Other hazards which do not result in classification

The product does not have other hazards. Adequate labeling elements

Signal word

DANGER SDS H225 Highly flammable liquid and vapour. H315 Causes skin irritation. H317 May cause an allergic skin reaction.

Hazard statements

H319 Causes serious eye irritation. H335 May cause respiratory irritation. H402 Harmful to aquatic life

Prevention

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof electrical, ventilating and lighting equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P261 Avoid breathing mist, vapours and spray. P264 Wash hands thoroughly after handling.

Precautionary statements

P271 Use only outdoors or in a well-ventilated area. P272 Contaminated work clothing should not be allowed out of the workplace. P273 Avoid release to the environment. P280 Wear protective gloves, protective clothing, eye protection and face protection.

Response

P302 + P352 IF ON SKIN: Wash with plenty water and soap. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower. P304 + P340 IF INHALED: Remove person to fresh air and keep SDS comfortable for breathing. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312 Call a POISON CENTER or a doctor, if you feel unwell. P321 Specific treatment. P332 + P313 If skin irritation occurs: Get medical advice/attention. P333 + P313 If skin irritation or rash occurs: Get medical advice/attention. P337 + P313 If eye irritation persists: Get medical advice. P362 + P364 Take off contaminated clothing and wash it before reuse. P370 + P378 In case of fire: Use carbon dioxide, water spray, alcohol resistant foam or chemical powder to extinguish.

Storage

P403 + P233 Store in a well-ventilated place. Keep container tightly closed. P403 + P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.

Disposal

P501 Dispose of contents and container in accordance with local regulations.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.