General Information
Revision date
2015-05-18
Product name
Quick Dry
CAS No.
70892-59-0
Manufacturer Name
PROFILE Products, LLC
Icons in SDS
Company Information
company name
PROFILE Products, LLC
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H335
Hazard statements
Code
Statements
H335
May cause respiratory irritation
Section 2
SECTION 2: Hazards identification
29 CFR 1910.1200) Inhalation: Lungs Skin Contact: Wash with soap and water until clean. Eye Contact: Wash out with water. Ingestion: No adverse effect. NFPA: Health = 1, Fire = 0, Reactivity = 0 0 1 0 Page 2 of 6
Signal word
WARNING
2.1 Classification of the substance or mixture
Health, Specific target organ toxicity - Single exposure, 3
Hazard statements
H335 - May cause respiratory irritation
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P261 - Avoid breathing dust/fume/gas/mist/vapours/spray. Crystalline Silica (Quartz) [EPA Hazard Category: Health] Carcinogen: OSHA - No NTP - Yes (respirable) IARC - Yes This product contains up to 5% crystalline silica. The International Agency for Research on Cancer (IARC) has stated that there is sufficient evidence of carcinogenicity of crystalline silica to human beings. It was noted that carcinogenicity was not detected in all industrial circumstances studied. The NTP's Sixth Annual Report on Carcinogens include respirable crystalline silica. The Hazard Communication Standard (29CFR 1910.1200) requires that any material containing over 0.1% of a substance reported as a carcinogen in an IARC monograph or the most recent NTP Annual Report on Carcinogens must be identified as a carcinogen. These identifications are for hazard communications only and do not serve as assessments of carcinogenic risk. Crystalline silica is known to cause silicosis. At dust levels below the recommended PEL exposure to the crystalline silica contained in this product should not present a health hazard. Inhalation of excessive concentrations of any dust, including this material, may lead to lung injury. As formulated, this product is not expected to form appreciable respirable crystalline silica dust from use or attrition. Because application and exposure data indicate exposure to respirable quartz in the normal use of the ingredient within this product which contains crystalline silica, is well below the OSHA Permissible Exposure Limit (PEL) and ACGIH Threshold Limit Value (TLV). Adverse effects would not be expected from normal use of this product