Note: Ingredients listed on restricted chemical lists
EC/CAS
215-138-9/1305-78-8
Name of the chemical
Calcium oxide
Concentration
2.5<=x%<10
General Information
Revision date
2022-11-15
Product name
MTA WHITE
1.2.1 Relevant identified uses
For dental professional use only To mix with distilled water
Icons in SDS
Company Information
company name
PRODUITS DENTAIRES SA
e-mail address of the competent person responsible for the Safety Data Sheet
info@pd-dental.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H315, H318, H335
Hazard statements
Code
Statements
H315
Causes skin irritation
Section 2
2.1 Classification of the substance or mixture
GHS compliant. Skin irritation, Category 2 (Skin Irrit. 2, H315). Serious eye damage, Category 1 (Eye Dam. 1, H318). Specific target organ toxicity (single exposure), Category 3 (STOT SE 3, H335). This mixture does not present a physical hazard. Refer to the recommendations regarding the other products present on the site. This mixture does not present an environmental hazard. No known or foreseeable environmental damage under standard conditions of use.
2.2 Label elements
GHS compliant.
Hazard pictograms
GHS05 GHS07
Signal word
DANGER
Product definition
CAS 12168-85-3 TRICALCIUM SILICATE CAS 12042-78-3 TRICALCIUM ALUMINATE CAS 10034-77-2 DICALCIUM SILICATE CAS 1305-78-8 CALCIUM OXIDE CAS 12068-35-8 FERROALUMINATO TRICALCIUM
Hazard statements
H315 Causes skin irritation. H318 Causes serious eye damage. H335 May cause respiratory irritation.
Prevention
P261 Avoid breathing dust. P264 Wash hands thoroughly after handling. P280 Wear protective gloves according to the hygienic rules in force in dental surgeries.
Response
P302 + P352 IF ON SKIN: Wash with plenty of water P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a doctor/physician. P332 + P313 If skin irritation occurs: Get medical advice/attention.
Precautionary statements
Disposal P501 Dispose of contents/container according to the hygienic rules in force in dental surgeries and according to the legislation in force.
2.3 Other hazards
In use, may form flammable/explosive dust-air mixture.