General Information
Product name
which in contact with water, emit flammable gases (Category 1), H260
Substance name
which in contact with water, emit flammable gases (Category 1), H260
CAS No.
917-64-6
1.2.1 Relevant identified uses
For the full text of the H-Statements mentioned in this Section, see Section 16
Icons in SDS
Section 2
Hazard pictograms
F Highly flammable C Corrosive
R-phrase(s)
R11 Highly flammable. R14/15 Reacts violently with water, liberating extremely flammable gases. R19 May form explosive peroxides. R22 Harmful if swallowed. R34 Causes burns. R67 Vapours may cause drowsiness and dizziness.
S-phrase(s)
S16 Keep away from sources of ignition - No smoking. S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S36/37/39 Wear suitable protective clothing, gloves and eye/face protection. S43 In case of fire, use sand, dry chemical or alcohol- resistant foam. S45 In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
Supplemental label elements
None
Other hazards
None 4.1 Description of first aid measures General Advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Wash off with soap and plenty of water. Consult a physician. In case of eye contact Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. If swallowed Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. 4.2 Most Important symptoms & efforts, both acute and delayed The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 1 4.3 Indication of any immediate medical attention and special treatment needed No data available 5.1 Extinguishing Media: Suitable extinguishing media Dry powder 5.2 Special hazards arising from the substance or mixture Carbon oxides, Hydrogen iodide, Magnesium oxide 5.3 Advice for firefighters Wear self contained breathing apparatus for fighting if necessary.
Further information
No data available. 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Avoid breathing dust. For personal protection see section 8. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet- brushing and place in container for disposal according to local regulations (see section 13). Do not flush with water. 6.4 Reference to other sections For disposal see section 13. 7.1 Precautions for safe Handling Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2. 7.2 Conditions for safe Storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Never allow product to get in contact with water during storage. Light sensitive. Air sensitive. Heat sensitive. Handle and store under inert gas. 7.3 Specific end uses Apart from the uses mentioned in section 1.2 no other specific uses are stipulated 8.1 Control parameters Components with workplace control Parameters. 8.2 Exposure Controls Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. Personal protective equipment Eye/face protection Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Body Protection impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backupto engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). Control of environmental exposure Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. 9.1 Information on Basic physical & chemical properties a) Appearance Form: liquid Colour: dark gray b) Odor no data available c) Odor Threshold no data available d) pH no data available e) Melting point/freezing no data available Point f) Initial boiling point and no data available g) Flash point -40 °C - closed cup h) Evaporation rate no data available i) Flammability (solid, gas) no data available j) Upper/lower no data available Flammability or explosive limits k) Vapor pressure no data available l) Vapor density no data available m) Relative density no data available n) Water solubility no data available o) Partition coefficient: n-octanol /water no data available p) Auto ignition no data available Temperature q) Decomposition no data available Temperature r) Viscosity no data available s) Explosive properties no data available t) Oxidizing properties no data available