General Information

Product name

2-iodo methyl benzoate

Icons in SDS

Company Information

company name

Infinium Pharmachem Pvt. Ltd.

Section 2

R-phrase(s)

R36/37/38 Irritating to eyes, respiratory system and skin.

S-phrase(s)

S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S36 Wear suitable protective clothing.

2.3 Other hazards

none. 4.1 Description of first aid measures General Advice Consult a physician. Show this safety data sheet to the doctor in attendance. If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician. In case of skin contact Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician. In case of eye contact Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. If swallowed Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. 4.2 Most Important symptoms & efforts, both acute and delayed To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. 4.3 Indication of any immediate medical attention and special treatment needed No data available 5.1 Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide. 5.2 Special hazards arising from the substance or mixture Hydrogen Iodide, carbon oxides 5.3 Advice for firefighters Wear self contained breathing apparatus for fighting if necessary.

Further information

No data available. 6.1 Personal precautions, protective equipment and emergency procedures Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. 6.2 Environmental precautions Do not let product enter drains. 6.3 Methods and materials for containment and cleaning up Soak up with inert absorbent material and dispose of as hazardous waste. Keep in suitable, closed containers for disposal. 6.4 Reference to other sections For disposal see section 13 7.1 Precautions for safe Handling Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. Normal measures for preventive fire protection. 7.2 Conditions for safe Storage, including any incompatibilities Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. 7.3 Specific end uses No data available. 8.1 Control parameters Components with workplace control Parameters. 8.2 Exposure Controls Appropriate engineering controls Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday. Personal protective equipment Eye/face protection Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Skin protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Body Protection impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Respiratory protection Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU). 9.1 Information on Basic physical & chemical properties

Appearance/Odor

Form: liquid no data available c) Odor Threshold no data available d) pH no data available e) Melting point/freezing no data available Point f) Initial boiling point and 149-150 °C at 13 hPa - lit Boiling range g) Flash point no data available h) Evaporation rate no data available i) Flammability (solid, gas) no data available j) Upper/lower no data available Flammability or explosive limits k) Vapor pressure no data available l) Vapor density no data available m) Relative density 1.784 g/cm3 at 25°C n) Water solubility no data available o) Partition coefficient: n-octanol /water no data available p) Auto ignition no data available Temperature q) Decomposition no data available Temperature r) Viscosity no data available s) Explosive properties no data available t) Oxidizing properties no data available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.