Note: Ingredients listed on restricted chemical lists
EC/CAS
200-661-7/67-63-0
Name of the chemical
Propan-2-ol
Concentration
>30%
EC/CAS
200-662-2/67-64-1
Name of the chemical
acetone
Concentration
5%≤C≤15
EC/CAS
204-696-9/124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
<5%
EC/CAS
203-474-9/107-22-2
Name of the chemical
Glyoxal
Concentration
<1%
EC/CAS
230-525-2/7173-51-5
Name of the chemical
Didecyldimethylammonium chloride
Concentration
<1%
General Information
Revision date
2018-10-02
Product name
B-CLEAN
1.2.2. Uses advised against
known
Emergency telephone
24h/24h (Telephone advice: English, French, German, Dutch
Icons in SDS
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H229, H319, H336
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
2.1 Classification of the substance or mixture
Classified as dangerous according to the criteria of Regulation (EC) No 1272/2008 Class Category
Hazard statements
Aerosol category 1 H222: Extremely flammable aerosol. Aerosol category 1 H229 Pressurised container May burst if heated Eye Irrit. category 2 H319: Causes serious eye irritation. STOT SE category 3 H336: May cause drowsiness or dizziness. H222 Extremely flammable aerosol. H229 Pressurised container: May burst if heated. H319 Causes serious eye irritaon. H336 May cause drowsiness or dizziness.
Contains
propan-2-ol glyoxal. May produce an allergic reaction
Signal word
Danger
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignion sources. No smoking. Created by: Brandweerinformatiecentrum voor gevaarlijke stoffen vzw (BIG) Publication date 2000-08-08 Technische Schoolstraat 43 A, B-2440 Geel Date of revision 2018-10-02 http://www.big.be © BIG vzw Reason for revision: 2; 3; 5; 9; 15 134-16239-625-en P211 Do not spray on an open flame or other ignion source. P251 Do not pierce or burn, even aer use. P280 Wear eye protecon P312 Call a POISON CENTER/doctor if you feel unwell. P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122°F.
Additional information
EUH208
2.3 Other hazards
Gas/vapour spreads at floor level: ignition hazard