General Information
Version
1.0
Revision date
2021-01-28
Product name
Nitrogen trifluoride
Substance name
Nitrogen trifluoride
Chemical name
Inorganic Halide
CAS No.
7783-54-2
1.2.1 Relevant identified uses
Industrial use; Use as directed
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Praxair, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H270, H280, H332, H373
Hazard statements
Code
Statements
H270
May cause or intensify fire; oxidiser
Section 2
SECTION 2: Hazards identification
GHS US classification Classification of the substance or mixture GHS US classification Ox. Gas 1 H270 Press. Gas (Liq.) H280 Acute Tox. 4 (Inhalation:gas) H332 STOT RE 2 H373
2.2 Label elements
GHS US labeling
Hazard pictograms
GHS03 GHS04 GHS07 GHS08
Signal word
Danger
Hazard statements
H270 - MAY CAUSE OR INTENSIFY FIRE; OXIDIZER H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H332 - HARMFUL IF INHALED H373 - MAY CAUSE DAMAGE TO ORGANS (KIDNEYS, LIVER, SPLEEN, CENTRAL NERVOUS SYSTEM, BLOOD) THROUGH PROLONGED OR REPEATED EXPOSURE CGA-HG10 - ASPHYXIATING EVEN WITH ADEQUATE OXYGEN. CGA-HG11 - SYMPTOMS MAY BE DELAYED CGA-HG01 - MAY CAUSE FROSTBITE.
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood. P220 - Keep/Store away from clothing, combustible materials EN (English US) SDS ID: P-4854 1/9 P244 - Keep reduction valves/valves and fittings free from oil and grease. P260 - Do not breathe gas P262 - Do not get in eyes, on skin, or on clothing. P271+P403 - Use and store only outdoors or in a well-ventilated place. P280+P284 - Wear protective gloves, protective clothing, eye protection, respiratory protection, and/or face protection. P302, P336, P315 - IF ON SKIN: Thaw frosted parts with lukewarm water. Do not rub affected area.. Get immediate medical advice/attention. P304-P340-P312 - IF INHALED: remove victim to fresh air and keep at rest in a position comfortable for breathing.Call a POISON CENTER/doctor if you feel unwell. P370+P376 - IN CASE OF FIRE: Stop leak if safe to do so P501 - Dispose of contents/container in accordance with local/regional/national/international regulations. Contact supplier for any special requirements. CGA-PG05 - Use a back flow preventive device in the piping. CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG22 - Use only with equipment cleaned for oxygen service. CGA-PG12 - Do not open valve until connected to equipment prepared for use. CGA-PG21 - Open valve slowly. CGA-PG06 - Close valve after each use and when empty. CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).
2.3 Other hazards
No additional information available
Ingredient(s) with unknown acute toxicity
No data available
2.1 Classification of the substance or mixture
GHS US classification Ox. Gas 1 H270 Press. Gas (Liq.) H280 Acute Tox. 4 (Inhalation:gas) H332 STOT RE 2 H373