Note: Ingredients listed on restricted chemical lists
EC/CAS
74-87-3
Name of the chemical
Chlormethan
Concentration
N/A
General Information
Revision date
2016-10-17
Product name
Methyl chloride (Refrigerant gas R 40)
Substance name
Methyl chloride (Refrigerant gas R 40)
CAS No.
74-87-3
Icons in SDS
Company Information
company name
Praxair, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H220, H280, H332, H351, H373
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
Classification (GHS-US)
Flam. Gas 1 H220 Liquefied gas H280 Acute Tox. 4 (Inhalation:gas) H332 Carc. 2 H351 STOT RE 2 H373
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS02 GHS04 GHS07 GHS08
Signal word
DANGER
Hazard statements
H220 - EXTREMELY FLAMMABLE GAS H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H332 - HARMFUL IF INHALED H351 - SUSPECTED OF CAUSING CANCER H373 - MAY CAUSE DAMAGE TO ORGANS (LUNG, KIDNEYS, LIVER, CENTRAL NERVOUS SYSTEM) THROUGH PROLONGED OR REPEATED EXPOSURE CGA-HG04 - MAY FORM EXPLOSIVE MIXTURES WITH AIR CGA-HG01 - MAY CAUSE FROSTBITE
Precautionary statements
P201 - Obtain special instructions before use P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from Heat, Open flames, Sparks, Hot surfaces. - No smoking P260 - Do not breathe gas P262 - Do not get in eyes, on skin, or on clothing P271+P403 - Use and store only outdoors or in a well-ventilated place P280+P284 - Wear protective gloves, protective clothing, eye protection, respiratory protection, and/or face protection P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P405 - Store locked up P501 - Dispose of contents/container in accordance with container Supplier/owner instructions CGA-PG05 - Use a back flow preventive device in the piping CGA-PG12 - Do not open valve until connected to equipment prepared for use CGA-PG06 - Close valve after each use and when empty CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F)
Other hazards which do not result in classification
Contact with liquid may cause cold burns/frostbite. 2.4.
Ingredient(s) with unknown acute toxicity
No data available