Ammonia

praxair, inc.

Revision date : 2016-10-13

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS04 GHS05 GHS07
Health risk rating 3
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7664-41-7

Name of the chemical

ammonia

Concentration

N/A

General Information

Revision date

2016-10-13

Product name

Ammonia

CAS No.

7664-41-7

Emergency telephone

(954) 603-9046

Icons in SDS

Company Information

company name

praxair, inc.

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H280, H314, H332

Hazard statements

Code

Statements

H280

Contains gas under pressure; may explode if heated

Section 2

Classification (GHS-US)

Liquefied gas H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1B H314

2.2 Label elements

GHS-US labeling

Hazard pictograms

GHS04 GHS05 GHS07

Signal word

DANGER

Hazard statements

H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE H332 - HARMFUL IF INHALED

Precautionary statements

P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from Heat, Open flames, Sparks, Hot surfaces. - No smoking P260 - Do not breathe gas P262 - Do not get in eyes, on skin, or on clothing P271+P403 - Use and store only outdoors or in a well-ventilated place P273 - Avoid release to the environment P280 - Wear protective gloves, protective clothing, eye protection, face protection P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P501 - Dispose of contents/container in accordance with container Supplier/owner instructions CGA-PG05 - Use a back flow preventive device in the piping CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure CGA-PG12 - Do not open valve until connected to equipment prepared for use CGA-PG06 - Close valve after each use and when empty CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F)

Other hazards which do not result in classification

Contact with liquid may cause cold burns/frostbite. 2.4.

Ingredient(s) with unknown acute toxicity

No data available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.