Note: Ingredients listed on restricted chemical lists
EC/CAS
7664-41-7
Name of the chemical
ammonia
Concentration
100%
General Information
Revision date
2015-09-10
Product name
Ammonia
Product Synonyms
AMMONIA
Chemical name
Ammonia
CAS No.
7664-41-7
Emergency telephone
1-800-645-4633, 1-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Praxair, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H280, H314, H332
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
Classification (GHS-US)
Liquefied gas H280 Acute Tox. 4 (Inhalation:gas) H332 Skin Corr. 1B H314
2.2 Label elements
GHS-US labeling
Hazard pictograms
GHS04 GHS05 GHS07
Signal word
DANGER
Hazard statements
H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED H314 - CAUSES SEVERE SKIN BURNS AND EYE DAMAGE H332 - HARMFUL IF INHALED
Precautionary statements
P202 - Do not handle until all safety precautions have been read and understood P210 - Keep away from Heat, Open flames, Sparks, Hot surfaces. - No smoking P260 - Do not breathe gas P262 - Do not get in eyes, on skin, or on clothing P271+P403 - Use and store only outdoors or in a well-ventilated place P273 - Avoid release to the environment P280 - Wear protective gloves, protective clothing, eye protection, face protection P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - Eliminate all ignition sources if safe to do so P501 - Dispose of contents/container in accordance with container Supplier/owner instructions CGA-PG05 - Use a back flow preventive device in the piping CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure EN (English US) SDS ID: P-4562 1/11 This document is only controlled while on the Praxair, Inc. website and a copy of this controlled version is available for download. Praxair cannot assure the integrity or accuracy of any version of this document after it has been downloaded or removed from our website. Safety Data Sheet P-4562 This SDS conforms to U.S. Code of Federal Regulations 29 CFR 1910.1200, Hazard Communication. Date of Issue 01/01/1981 Date Updated 10/13/2016 Supersedes: 03/23/2015 CGA-PG12 - Do not open valve until connected to equipment prepared for use CGA-PG06 - Close valve after each use and when empty CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F)
Other hazards which do not result in classification
Contact with liquid may cause cold burns/frostbite. 2.4.
Ingredient(s) with unknown acute toxicity