Note: Ingredients listed on restricted chemical lists
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
≥1.0-≤5.0
EC/CAS
872-50-4
Name of the chemical
N-Methyl-2-Pyrrolidone; 1-methyl-2-pyrrolidone (NMP)
Concentration
<1.0
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
<1.0
General Information
Revision date
2016-04-22
Product name
MACHINECOAT PLUS BLACK BASE
Manufacturer Name
PPG Industries, Inc
Icons in SDS
Company Information
company name
PPG Industries, Inc
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
29 CFR 1910.1200) OSHA/HCS status : This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
2.1 Classification of the substance or mixture
CARCINOGENICITY - Category 1A TOXIC TO REPRODUCTION (Unborn child) - Category 1B
Ingredient(s) with unknown acute toxicity
39.9%
Signal word
Danger
Hazard statements
May cause cancer. May damage the unborn child.
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear protective gloves. Wear eye or face protection. Wear protective clothing.
Response
IF exposed or concerned: Get medical attention. Photosensitive agents : In case of accidental eye contact, avoid concurrent exposure to the sun or other sources of UV light which may increase the sensitivity of the eyes. In case of accidental skin contact, avoid concurrent exposure to the sun or other sources of UV light which may increase the sensitivity of skin.
Storage
Store locked up.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Sanding and grinding dusts may be harmful if inhaled. This product contains crystalline elements silica which can cause lung cancer or silicosis. The risk of cancer depends on the duration and level of exposure to dust from sanding surfaces or mist from spray applications. Repeated exposure to high vapor concentrations may cause irritation of the respiratory system and permanent brain and nervous system damage. Inhalation of vapor/aerosol concentrations above the recommended exposure limits causes headaches, drowsiness and nausea and may lead to unconsciousness or death. Avoid contact with skin and clothing. Wash thoroughly after handling. Emits toxic fumes when heated.
2.3 Other hazards
Prolonged or repeated contact may dry skin and cause irritation.