Note: Ingredients listed on restricted chemical lists
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
≥20-≤50 ≥1.0-≤5.0
EC/CAS
552-30-7
Name of the chemical
Benzene-1,2,4-tricarboxylic acid 1,2-anhydride
Concentration
<1.0
General Information
Version
4
Revision date
2023-08-02
Product name
ENVIROCRON
1.2.1 Relevant identified uses
Industrial applications
1.2.2. Uses advised against
Coating. Paints. Painting-related materials
Manufacturer Name
PPG Industries, Inc
Emergency telephone
1-888-774-2001
Icons in SDS
Company Information
company name
PPG Industries, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H334, H335, H351
Hazard statements
Code
Statements
H334
May cause allergy or asthma symptoms or breathing difficulties if inhaled
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture RESPIRATORY SENSITIZATION - Category 1 CARCINOGENICITY - Category 2 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Respiratory tract irritation) - Category 3
Ingredient(s) with unknown acute toxicity
44% (oral), 64.6% (dermal), 75.2% (inhalation)
Signal word
Danger
Hazard statements
H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled. H335 - May cause respiratory irritation. H351 - Suspected of causing cancer.
Prevention
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear protective gloves, protective clothing and eye or face protection. P284 - Wear respiratory protection. P271 - Use only outdoors or in a well-ventilated area. P261 - Avoid breathing dust or mist.
Response
P308 + P313 - IF exposed or concerned: Get medical advice or attention. P304 + P340, P312 - IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor if you feel unwell. P342 + P311 - If experiencing respiratory symptoms: Call a POISON CENTER or doctor.
Storage
P405 - Store locked up. P403 + P233 - Store in a well-ventilated place. Keep container tightly closed.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national and international regulations.
Other hazards which do not result in classification
Handling and/or processing of this material may generate a dust which can cause mechanical irritation of the eyes, skin, nose and throat. Emits toxic fumes when heated. See toxicological information (Section 11)
2.1 Classification of the substance or mixture
RESPIRATORY SENSITIZATION - Category 1 substance or mixture CARCINOGENICITY - Category 2 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Respiratory tract irritation) - Category 3 Percentage of the mixture consisting of ingredient(s) of unknown acute toxicity: 44% (oral), 64.6% (dermal), 75.2% (inhalation)