Note: Ingredients listed on restricted chemical lists
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
30-60
EC/CAS
74227-35-3
Name of the chemical
A mixture of: thiobis(4,1-phenylene)-S,S,S',S'-tetraphenyldisulfonium bishexafluorophosphate; diphenyl(4-phenylthiophenyl)sulfonium hexafluorophosphate
Concentration
N/A
EC/CAS
21645-51-2
Name of the chemical
Aluminium hydroxide
Concentration
1-5
General Information
Version
7.01
Revision date
2025-03-01
Product name
PVDF WHITE PASTE
1.2.1 Relevant identified uses
Industrial applications
supplier name
PPG Canada Inc
Icons in SDS
Company Information
company name
PPG Canada Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H351, H373
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
Classification of the substance or mixture FLAMMABLE LIQUIDS - Category 3 Physical Hazards Not Otherwise Classified - Category 1 CARCINOGENICITY - Category 2 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2 Health Hazards Not Otherwise Classified - Category 1 This product contains TiO2 which has been classified as a GHS Carcinogen Category 2 based on its IARC 2B classification. For many products, TiO2 is utilized as a raw material in a liquid coating formulation. In this case, the TiO2 particles are bound in a matrix with no meaningful potential for human exposure to unbound particles of TiO2 when the product is applied with a brush or roller. Sanding the coating surface or mist from spray applications may be harmful depending on the duration and level of exposure and require the use of appropriate personal protective equipment and/or engineering controls (see Section 8)
Signal word
Danger
Hazard statements
Flammable liquid and vapor. Suspected of causing cancer. May cause damage to organs through prolonged or repeated exposure. May form explosive peroxides. Prolonged or repeated contact may dry skin and cause irritation.
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear protective gloves, protective clothing and eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not breathe vapor.
Response
IF exposed or concerned: Get medical advice or attention. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
Storage
Store locked up.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Hazardous reactions or instability may occur under certain conditions of storage or use. Repeated exposure to high vapor concentrations may cause irritation of the respiratory system and permanent brain and nervous system damage. Inhalation of vapor/aerosol concentrations above the recommended exposure limits causes headaches, drowsiness and nausea and may lead to unconsciousness or death. Avoid contact with skin and clothing. Wash thoroughly after handling. Emits toxic fumes when heated. Percentage of the mixture consisting of ingredient(s) of unknown acute toxicity: 9.2% (oral), 15.4% (dermal), 15.4% (inhalation)
2.1 Classification of the substance or mixture
FLAMMABLE LIQUIDS - Category 3 substance or mixture Physical Hazards Not Otherwise Classified - Category 1 CARCINOGENICITY - Category 2 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2 Health Hazards Not Otherwise Classified - Category 1 This product contains TiO2 which has been classified as a GHS Carcinogen Category 2 based on its IARC 2B classification. For many products, TiO2 is utilized as a raw material in a liquid coating formulation. In this case, the TiO2 particles are bound in a matrix with no meaningful potential for human exposure to unbound particles of TiO2 when the product is applied with a brush or roller. Sanding the coating surface or mist from spray applications may be harmful depending on the duration and level of exposure and require the use of appropriate personal protective equipment and/or engineering controls (see Section 8).