Note: Ingredients listed on restricted chemical lists
EC/CAS
822-06-0
Name of the chemical
Hexamethylene diisocyanate
Concentration
<1.0
General Information
Version
7.03
Revision date
2021-06-22
Product name
CA 8100B CURING SOLUTION
Manufacturer Name
PPG Aerospace PRC-DeSoto
Emergency telephone
(412) 434-4515 (U.S.
Icons in SDS
Company Information
company name
PPG Aerospace PRC-DeSoto
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
ACUTE TOXICITY (inhalation) - Category 4 RESPIRATORY SENSITIZATION - Category 1 SKIN SENSITIZATION - Category 1 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Respiratory tract irritation) - Category 3
Signal word
Danger
Hazard statements
May cause an allergic skin reaction. Harmful if inhaled. May cause allergy or asthma symptoms or breathing difficulties if inhaled. May cause respiratory irritation.
Prevention
Wear protective gloves. Wear respiratory protection. Use only outdoors or in a well- ventilated area. Avoid breathing vapor. Contaminated work clothing must not be allowed out of the workplace.
Response
IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor if you feel unwell. If experiencing respiratory symptoms: Call a POISON CENTER or doctor. Wash contaminated clothing before reuse. IF ON SKIN Wash with plenty of water. If skin irritation or rash occurs Get medical advice or attention.
Storage
Store locked up. Store in a well-ventilated place. Keep container tightly closed.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
Supplemental label elements
Moisture-sensitive material. Skin contact to isocyanate monomer may lead to allergic elements lung reaction. Based on the properties of the isocyanate components and considering toxicological data on similar mixtures, this mixture may cause acute irritation and/or sensitization of the respiratory system, leading to an asthmatic condition, wheezing and tightness of the chest. Sensitized persons may subsequently show asthmatic symptoms when exposed to atmospheric concentrations well below the OEL. Repeated exposure may lead to permanent respiratory disability. Persons with a history of skin sensitization problems or asthma, allergies or chronic or recurrent respiratory disease should not be employed in any process in which this product is used. Emits toxic fumes when heated.
2.3 Other hazards
None known.