Note: Ingredients listed on restricted chemical lists
EC/CAS
8052-41-3
Name of the chemical
Stoddard solvent; Low boiling point naphtha — unspecified (A colourless, refined petroleum distillate that is free from rancid or objectionable odours and that boils in a range of approximately 149 °C to 205 °C.)
Concentration
≥50-≤75
EC/CAS
64742-82-1
Name of the chemical
Naphtha (petroleum), hydrodesulfurized heavy
Concentration
≥10-<20
EC/CAS
96-29-7
Name of the chemical
2-Butanonoxim (2020/1182)
Concentration
≤0.3
General Information
Version
4.04
Revision date
2023-02-22
Product name
ALBA FIJADOR AL AGUARRAS STANDARD
supplier name
Pinturas INCA SA
Icons in SDS
Company Information
company name
Pinturas INCA SA
e-mail address of the competent person responsible for the Safety Data Sheet
inca@akzonobel.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H350, H373, H411
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
H350
May cause cancer
H373
May cause damage to organs through prolonged or repeated exposure
H411
Toxic to aquatic life with long lasting effects
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
FLAMMABLE LIQUIDS - Category 3 SPECIFIC TARGET ORGAN TOXICITY - REPEATED EXPOSURE (respiratory system) - Category 2 LONG-TERM (CHRONIC) AQUATIC HAZARD - Category 2
Signal word
Danger
Hazard statements
H226 - Flammable liquid and vapour. H350 - May cause cancer. H373 - May cause damage to organs through prolonged or repeated exposure. (respiratory system) H411 - Toxic to aquatic life with long lasting effects.
Precautionary statements
General : P102 - Keep out of reach of children. P101 - If medical advice is needed, have product container or label at hand.
Prevention
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P280 - Wear protective gloves. Wear eye or face protection. Wear protective clothing. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P241 - Use explosion-proof electrical, ventilating, lighting and all material-handling equipment. P242 - Use only non-sparking tools. P243 - Take precautionary measures against static discharge. P233 - Keep container tightly closed. P273 - Avoid release to the environment. P260 - Do not breathe vapour.
Response
P391 - Collect spillage. P314 - Get medical attention if you feel unwell. P308 + P313 - IF exposed or concerned: Get medical attention. P303 + P361 + P353 - IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower.
Storage
P405 - Store locked up. P403 + P235 - Store in a well-ventilated place. Keep cool.
Disposal
P501 - Dispose of contents and container in accordance with all local, regional, national or international regulations.
Other hazards which do not result in classification
None known.