General Information
Product name
Megaflow AW Hydraulic Oil
CAS No.
64742-54-7
Emergency telephone
1-877-445-9198
Icons in SDS
Company Information
company name
Phillips 66 Lubricants
e-mail address of the competent person responsible for the Safety Data Sheet
SDS@P66.com
Section 2
SECTION 2: Hazards identification
(29 CFR 1910.1200) Classified Hazards Hazards Not Otherwise Classified (HNOC)
2.2 Label elements
No classified hazards
2.1 Classification of the substance or mixture
Hazards Not Otherwise Classified (HNOC) This material is not hazardous under the criteria of the Federal OSHA Hazard PHNOC: None known Communication Standard 29CFR 1910.1200. HHNOC: None known Label Elements No classified hazards SECTION 3: Composition/information on ingredients Chemical Name CASRN Concentration¹ Distillates, petroleum, hydrotreated heavy paraffinic 64742-54-7 >99 ¹ All concentrations are percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume. SECTION 4: First aid measures Eye Contact: If irritation or redness develops from exposure, flush eyes with clean water. If symptoms persist, seek medical attention. Skin Contact: First aid is not normally required. However, it is good practice to wash any chemical from the skin. If product is Injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician. (see Note to Physician) Inhalation: First aid is not normally required. If breathing difficulties develop, move victim away from source of exposure and into fresh air in a position comfortable for breathing. Seek immediate medical attention. Ingestion: First aid is not normally required; however, if swallowed and symptoms develop, seek medical attention. 7 Most important symptoms and effects, both acute and delayed: Inhalation of oil mists or vapors generated at elevated temperatures may cause respiratory irritation. Accidental ingestion can result in minor irritation of the digestive tract, nausea and diarrhea. Notes to Physician: Acute aspirations of large amounts of oil-laden material may produce a serious aspiration pneumonia. Patients who aspirate these oils should be followed for the development of long-term sequelae. Inhalation exposure to oil mists below current workplace exposure limits is unlikely to cause pulmonary abnormalities. When using high-pressure equipment, injection of product under the skin can occur. In this case, the casualty should be sent immediately to the hospital. Do not wait for symptoms to develop. High-pressure hydrocarbon injection injuries may produce substantial necrosis of underlying tissue despite an innocuous appearing external wound. These injuries often require extensive emergency surgical debridement and all injuries should be evaluated by a specialist in order to assess the extent of injury. Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury. SECTION 5: Firefighting measures NFPA 704 Hazard Class Health: 0 Flammability: 1 Instability: 0 0 (Minimal) 1(Slight) 2 (Moderate) 3 (Serious) 4 (Severe) Extinguishing Media: Dry chemical, carbon dioxide, foam, or water spray is recommended. Water or foam may cause frothing of materials heated above 212°F / 100°C. Carbon dioxide can displace oxygen. Use caution when applying carbon dioxide in confined spaces. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam. Specific hazards arising from the chemical Unusual Fire & Explosion Hazards: This material may burn, but will not ignite readily. If container is not properly cooled, it can rupture in the heat of a fire. Hazardous Combustion Products: Combustion may yield smoke, carbon monoxide, and other products of incomplete combustion. Oxides of sulfur, nitrogen or phosphorus may also be formed. Special protective actions for firefighters: For fires beyond the initial stage, emergency responders in the immediate hazard area should wear protective clothing. When the potential chemical hazard is unknown, in enclosed or confined spaces, a self contained breathing apparatus should be worn. In addition, wear other appropriate protective equipment as conditions warrant (see Section 8). Isolate the hazard area and deny entry to unnecessary and unprotected personnel Stop spill/release if it can be done safely. Move undamaged containers from immediate hazard area if it can be done safely Water spray may be useful in minimizing or dispersing vapors and to protect personnel. Cool equipment exposed to fire with water, if it can be done safely. Avoid spreading burning liquid with water used for cooling purposes. See Section 9 for Flammable Properties including Flash Point and Flammable (Explosive) Limits SECTION 6: Accidental release measures Personal precautions, protective equipment and emergency procedures: This material may burn, but will not ignite readily. Keep all sources of ignition away from spill/release. Stay upwind and away from spill/release. Avoid direct contact with material. For large spillages, notify persons down wind of the spill/release, isolate immediate hazard area and keep unauthorized personnel out. Wear appropriate protective equipment, including respiratory protection, as conditions warrant (see Section 8). See Sections 2 and 7 for additional information on hazards and precautionary measures. 8 Environmental Precautions: Stop and contain spill/release if it can be done safely. Prevent spilled material from entering sewers, storm drains, other unauthorized drainage systems, and natural waterways. Use water sparingly to minimize environmental contamination and reduce disposal requirements. If spill occurs on water notify appropriate authorities and advise shipping of any hazard. Spills into or upon navigable waters, the contiguous zone, or adjoining shorelines that cause a sheen or discoloration on the surface of the water, may require notification of the National Response Center (phone number 800-424-8802). Methods and material for containment and cleaning up: Notify relevant authorities in accordance with all applicable regulations. Immediate cleanup of any spill is recommended. Dike far ahead of spill for later recovery or disposal. Absorb spill with inert material such as sand or vermiculite, and place in suitable container for disposal. If spilled on water remove with appropriate methods (e.g. skimming, booms or absorbents). In case of soil contamination, remove contaminated soil for remediation or disposal, in accordance with local regulations. Recommended measures are based on the most likely spillage scenarios for this material; however local conditions and regulations may influence or limit the choice of appropriate actions to be taken. See Section 13 for information on appropriate disposal. SECTION 7: Handling and storage Precautions for safe handling: Keep away from flames and hot surfaces. Wash thoroughly after handling. Use good personal hygiene practices and wear appropriate personal protective equipment (see section 8). Spills will produce very slippery surfaces. High pressure injection of hydrocarbon fuels, hydraulic oils or greases under the skin may have serious consequences even though no symptoms or injury may be apparent. This can happen accidentally when using high pressure equipment such as high pressure grease guns, fuel injection apparatus or from pinhole leaks in tubing of high pressure hydraulic oil equipment. Do not enter confined spaces such as tanks or pits without following proper entry procedures such as ASTM D-4276 and 29CFR 1910.146. Do not wear contaminated clothing or shoes. Conditions for safe storage: Keep container(s) tightly closed and properly labeled. Use and store this material in cool, dry, well- ventilated area away from heat and all sources of ignition. Store only in approved containers. Keep away from any incompatible material (see Section 10). Protect container(s) against physical damage. "Empty" containers retain residue and may be dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, or other sources of ignition. They may explode and cause injury or death. "Empty" drums should be completely drained, properly bunged, and promptly shipped to the supplier or a drum reconditioner. All containers should be disposed of in an environmentally safe manner and in accordance with governmental regulations. Before working on or in tanks which contain or have contained this material, refer to OSHA regulations, ANSI Z49.1, and other references pertaining to cleaning, repairing, welding, or other contemplated operations. SECTION 8: Exposure controls/personal protection Chemical Name ACGIH OSHA Phillips 66 Distillates, petroleum, hydrotreated heavy --- TWA: 5 mg/m3 paraffinic STEL: 10 mg/m3 as Oil Mist, if Generated Note: State, local or other agencies or advisory groups may have established more stringent limits. Consult an industrial hygienist or similar professional, or your local agencies, for further information. Engineering controls: If current ventilation practices are not adequate to maintain airborne concentrations below the established exposure limits, additional engineering controls may be required. Eye/Face Protection: The use of eye/face protection is not normally required; however, good industrial hygiene practice suggests the use of eye protection that meets or exceeds ANSI Z.87.1 whenever working with chemicals. Skin/Hand Protection: The use of skin protection is not normally required; however, good industrial hygiene practice suggests the use of gloves or other appropriate skin protection whenever working with chemicals. Suggested protective materials: Nitrile Respiratory Protection: Where there is potential for airborne exposure above the exposure limit a NIOSH certified air purifying respirator equipped with R or P95 filters may be used. A respiratory protection program that meets or is equivalent to OSHA 29 CFR 1910.134 and ANSI Z88.2 should be followed whenever workplace conditions warrant a respirator's use. Air purifying respirators provide limited protection and cannot be used in atmospheres that exceed the maximum use concentration (as directed by regulation or the manufacturer's instructions), in oxygen deficient (less than 19.5 percent oxygen) situations, or under conditions that are immediately dangerous to life and health (IDLH). 9 Suggestions provided in this section for exposure control and specific types of protective equipment are based on readily available information. Users should consult with the specific manufacturer to confirm the performance of their protective equipment. Specific situations may require consultation with industrial hygiene, safety, or engineering professionals. SECTION 9: Physical and chemical properties Note: Unless otherwise stated, values are determined at 20°C (68°F) and 760 mm Hg (1 atm). Data represent typical values and are not intended to be specifications. Appearance: Amber, Transparent Flash Point: > 302 °F / > 150 °C (ASTM D93) Physical Form: Liquid Test Method: Pensky-Martens Closed Cup (PMCC), ASTM D93, EPA 1010 Odor: Petroleum Initial Boiling Point/Range: No data Odor Threshold: No data Vapor Pressure: <1 mm Hg pH: Not applicable Partition Coefficient (n-octanol/water) (Kow): No data Vapor Density (air=1): >1 Melting/Freezing Point: No data Upper Explosive Limits (vol % in air): No data Auto-ignition Temperature: No data Lower Explosive Limits (vol % in air): No data Decomposition Temperature: No data Evaporation Rate (nBuAc=1): No data Specific Gravity (water=1): 0.85-0.89 @ 60ºF (15.6ºC) Particle Size: Not applicable Bulk Density: No data Percent Volatile: No data Viscosity: 4.0 - 25 cSt @ 100°C; 21 - 345 cSt @ 40°C Flammability (solid, gas): Not applicable Pour Point: < 10 °F / < -12 °C Solubility in Water: Negligible SECTION 10: Stability and reactivity Reactivity: Not chemically reactive. Chemical stability: Stable under normal ambient and anticipated conditions of use. Possibility of hazardous reactions: Hazardous reactions not anticipated. Conditions to avoid: Extended exposure to high temperatures can cause decomposition. Avoid all possible sources of ignition. Incompatible materials: Avoid contact with strong oxidizing agents and strong reducing agents. Hazardous decomposition products: Not anticipated under normal conditions of use. SECTION 11: Toxicological information