Note: Ingredients listed on restricted chemical lists
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
General Information
Revision date
2017-01-12
Product name
PENECOAT TM TOP CLEAR
1.2.1 Relevant identified uses
Protective polishing varnish for structural porous materials
1.2.2. Uses advised against
No relevant identified uses-mixture of substances
Emergency telephone
European Emergency Tel.: 112
Icons in SDS
Company Information
company name
PENETRON HELLAS S.A
e-mail address of the competent person responsible for the Safety Data Sheet
info@penetron.gr
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H226, H315
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
According to Regulation (EC) No 1272/2008 [CLP]
CLP CLASSIFICATION
GHS02 flame Flam. Liq. 3 H226 Flammable liquid and vapour. GHS07 Skin Irrit. 2 H315 Causes skin irritation.
2.2 Label elements
Labelling according to Regulation EC No 1272/2008 CLP: The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS02 GHS07
Hazard statements
H226 Flammable liquid and vapour. H315 Causes skin irritation.
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ventilating/lighting equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge. P264 Wash hands thoroughly after handling. P280 Wear protective gloves/protective clothing/eye protection/face protection. P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower. P501 Dispose of contents/container in accordance with local/regional/national/international regulations.
Classification system
The classification of the product is according the European Chemicals Agency index, but it is also based to additional scientific bibliography and company data.
PBT Substances
Not applicable
vPvB Substances