Note: Ingredients listed on restricted chemical lists
EC/CAS
231-100-4/7439-92-1
Name of the chemical
Blei, massiv: [Partikeldurchmesser ≥ 1 mm]
Concentration
50%
Listed in
EC/CAS
215-174-5/1309-60-0
Name of the chemical
Lead peroxide
Concentration
10%
EC/CAS
231-198-9/7446-14-2
Name of the chemical
Lead sulphate
Concentration
10%
EC/CAS
231-639-5/7664-93-9
Name of the chemical
sulphuric acid
Concentration
20%
EC/CAS
231-141-8/7440-31-5
Name of the chemical
Organometallic tin
Concentration
0-0.25%
EC/CAS
231-148-6/7440-38-2
Name of the chemical
Arsenic (As)
Concentration
N/A
General Information
Revision date
2011-12-02
Product name
This MSDS applies only to products bearing this trademark
Product Synonyms
Sealed Lead-Acid Batteries (SLA), Valve Regulated Lead-Acid Batteries (VRLA), AbsorbedGlass Mat Batteries (AGM), Sealed Lead Calcium Batteries, Sealed Maintenance Free Lead-Acid Batteries
1.2.1 Relevant identified uses
Electric Storage Battery Prepared by: Environmental, Health and Safety Department; GS Battery – Canada (613-228-5000)
supplier name
Peak Energy Products
Manufacturer Name
Peak Energy Products
Icons in SDS
Company Information
company name
Peak Energy Products
Hazard Codes
Hazard statements (CLP)
H315, H320, H335
Hazard statements
Code
Statements
H315
Causes skin irritation
H320
Causes eye irritation
H335
May cause respiratory irritation
Section 2
SECTION 2: Hazards identification
67/548/EEC GHS Classification Health Environmental Physical Acute Toxicity – Not listed Aquatic Toxicity - Not listed NFPA –Flammable gas, hydrogen Eye Corrosion – Corrosive under severe overcharge Skin Corrosion – Corrosive conditions) Skin Sensitization – Not listed CN- Not listed Mutagency / Carcinogency – Not listed EU- Not listed Reproductive / Developmental – Not listed Target Organ Toxicity (Repeatedly)- Not listed as sulfuric acid
2.2 Label elements
Valve Regulated Lead Acid Battery, Non-Spillable
Hazard statements
C (Corrosive) Contact with internal components may cause irritation or severe burns. Irritating to eyes, respiratory system, and skin.
Precautionary statements
Keep out of reach of children. Do not attempt to remove Placards are only required for transportation of spent or cover. Avoid heat, sparks and open flame while charging batteries. Avoid contact with internal acid. damaged batteries destined for reclamation (recycling). Cont’d … Identification…continued 2.1 Emergency Overview Non-spillable batteries are sealed and do not leak or vent gasses under normal conditions. Under severe overcharge conditions venting of sulfuric acid gas and hydrogen can occur. Hydrogen gas is extremely flammable. Most hazards are presented during reclamation (recycling). If battery is ruptured or damaged, exposure to sulfuric acid electrolyte and lead can occur. Some battery terminals contain lead. After contact with terminals, wash hands before eating, drinking, smoking, applying cosmetics or handling contact lenses. Sulfuric Acid Appearance: colourless, oily fluid; vapours are colourless with acrid odor. Sulfuric Acid is a strong corrosive. Contact with sulfuric acid can cause burns on the skin and in eyes. Exposure to sulfuric acid fumes will cause respiratory and eye irritation, difficulty breathing, headache, nausea, and weakness. Severe overexposure may cause lung edema (swelling from fluid retention). Ingestion of Sulfuric Acid will cause GI (gastrointestinal) tract burns. Each non-spillable battery contains only enough sulfuric acid to saturate fiberglass separators, so a large spill is not likely to occur. Hazard is primarily through direct contact with internal components or through inhalation of gases under severe overcharge conditions. Sulfuric acid vapour is considered carcinogenic to humans (Group 1) by the International Agency for Research on Cancer (IARC). Lead (Pb) and Lead Compounds Appearance: bluish white, silvery grey. Lead may be absorbed through intact skin. Absorption or ingestion of lead may cause poisoning, central nervous system depression, kidney damage, reproductive toxicity and fetal effects. The toxic effects of Lead are accumulative and slow to appear. The symptoms of Lead overexposure are anemia, vomiting, headache, stomach pain (lead colic), dizziness, loss of appetite and muscle and joint pain. Exposure to lead from a battery most often occurs during lead reclaim operations and through the breathing or ingestion of lead dust or fumes. Lead is dangerous to the environment. Lead is considered carcinogenic to animals at extreme doses (Group 2B) by the International Agency for Research on Cancer (IARC). Fiberglass Separator Fiberglass is an irritant of the upper respiratory tract, skin and eyes. Fiberglass is not considered carcinogenic
Potential health effects
Sulfuric Acid Eye: Corrosive. Causes redness, pain and severe deep burns. Skin: Corrosive. Causes redness, pain, blisters and serious skin burns. Ingestion: Corrosive. Ingestion of sulfuric acid causes abdominal pain, burning sensation, shock or collapse. Inhalation: Corrosive. Inhalation of sulfuric acid may cause burning sensation in the nose and respiratory tract, sore throat, cough, laboured breathing, shortness of breath. Inhalation of sulfuric acid fumes may cause lung edema (swelling from fluid retention). Symptoms may be delayed and may not become apparent until a few hours have passed and lungs have been aggravated by physical effort. Chronic: Chronic exposure to sulfuric acid fumes may cause lung damage. There is risk of tooth erosion upon repeated or prolonged exposure to sulfuric acid fumes. Identification…continued Lead (Pb) and Lead Compounds Eye: Causes eye irritation. Skin: Causes skin irritation. May be absorbed through skin. Ingestion: Toxic. Causes gastrointestinal irritation with nausea, vomiting and diarrhea. Ingestion of lead compounds can cause toxic effects in the blood forming organs, kidneys and central nervous system. Symptoms of lead poisoning or plumbism include weakness, weight loss, lassitude, insomnia, and hypertension. It also includes constipation, anorexia, abdominal discomfort and colic. Inhalation: Toxic. May cause respiratory tract irritation. Inhalation of lead fumes may cause metal fume fever, which is characterized by flu-like symptoms with metallic taste, fever, chills, cough, weakness, chest pain, muscle pain and increased white blood cell count. May cause effects similar to those described for ingestion. Chronic: Chronic exposure may cause reproductive disorders and teratogenic effects. Chronic exposure to lead may result in plumbism, which is characterized by lead line in gum, headache, muscle weakness and mental changes.
Environmental effects
Sulfuric acid is harmful to aquatic organisms. Trace amounts of lead can make water unfit for consumption. Sulfuric acid and lead can contaminate food and feedstuffs. See also: Section 11 – Toxicological Information for additional data.
2.1 Classification of the substance or mixture
Environmental Physical Acute Toxicity – Not listed Aquatic Toxicity - Not listed NFPA –Flammable gas, hydrogen Eye Corrosion – Corrosive* (under severe overcharge Skin Corrosion – Corrosive* conditions) Skin Sensitization – Not listed CN- Not listed Mutagency / Carcinogency – Not listed EU- Not listed Reproductive / Developmental – Not listed Target Organ Toxicity (Repeatedly)- Not listed * as sulfuric acid GHS Label: Valve Regulated Lead Acid Battery, Non-Spillable