Note: Ingredients listed on restricted chemical lists
EC/CAS
68475-59-2
Name of the chemical
Petroleum, coal, tar and natural gas and their derivatives generated using distillation and/or other processing methods if they contain ≥ 0,1 % w/w 1,3-butadiene Alkanes, C3-4, if they contain > 0,1 % w/w Butadiene
Concentration
3-4
General Information
Revision date
2022-06-01
Product name
WELLER BUTANE GAS REFILL
CAS No.
68475-59-2
1.2.1 Relevant identified uses
Dispenser for refilling a range of Cooper Brand Tools
Icons in SDS
Company Information
company name
PASCOE"S PTY LTD
GHS Information
Signal word
DANGER
Hazard Codes
Hazard statements (CLP)
H222, H229
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
SECTION 2: Hazards identification
GHS Classification GHS classification of the substance/mixture Flammable Aerosol: Category 1
Signal word
DANGER Hazard Statement (s) H222 Extremely flammable aerosol H229 Pressurized container: may burst if heated Pictogram (s) Flame Precautionary Statement – Prevention P210 Keep away from heat/sparks/open flames/hot surfaces. – No smoking P211 Do not spray on an open flame or other ignition source P251 Pressurized container: Do not pierce or burn, even after use P102 Keep out of reach of children P233 Keep container tightly closed P261 Avoid breathing dust/fume/gas/mist/vapours/spray P262 Do not get in eyes, on skin, or on clothing P281 Use personal protective equipment as required Precautionary Statement – Response P301+P330+P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower P370+P378 In case of fire: Use carbon dioxide, dry chemical, foam, water fog. Water fog or fine spray is the preferred medium for large fires./ for extinction P372 Explosion risk in case of fire Precautionary Statement – Storage P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50ºC/122ºF P402 Store in a dry place P403 Store in a well-ventilated place
Precautionary statements
Disposal P501 Dispose of small quantities and empty containers by wrapping with paper and putting in garbage. For larger quantities, if recycling or reclaiming is not possible, use a commercial waste disposal service.
SUSMP Classification
None allocated
ADG classification
Class 2.1 Flammable gases Classified as a Dangerous Good for transport in accordance with the Land Transport Rule Dangerous Goods 2005 and NZS 5433:2007. Emergency Overview: Physical Description & Colour: Dispenses as a gas. Odour: Characteristic odour.
UN Number
1950, AEROSOLS
Hazard statements
(New Zealand) Aerosols Flammable Group Standard 2020 HSR002515
Health hazards
no significant risk factors have been found for this product
2.1 Classification of the substance or mixture
Flammable Aerosol: Category 1 Signal Word (s) DANGER Hazard Statement (s) H222 Extremely flammable aerosol. H229 Pressurized container: may burst if heated. Pictogram (s) Flame