General Information
Version
3
Revision date
2024-01-24
Product name
Silicon(IV) chloride
Product Synonyms
Silicon tetrachloride; Tetrachlorosilane
CAS No.
10026-04-7
Emergency telephone
001-800-227-6701, +32 14 57 52 11, 001-201-796-7100, +32 14 57 52 99, 001-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Part of Thermo Fisher Scientific)
e-mail address of the competent person responsible for the Safety Data Sheet
begel.sdsdesk@thermofisher.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H301+H331, H314, H318, H331, H335
Hazard statements
Code
Statements
H301
Toxic if swallowed
H301+H331
Toxic if swallowed or if inhaled
H314
Causes severe skin burns and eye damage.
H318
Causes serious eye damage.
H331
Toxic if inhaled
H335
May cause respiratory irritation
Section 2
SECTION 2: Hazards identification
Physical hazards
______________________________________________________________________________________________ ALFAA69182 Page 1 / 11 Based on available data, the classification criteria are not met
Health hazards
Acute oral toxicity Category 3 (H301) Acute Inhalation Toxicity - Vapors Category 3 (H331) Skin Corrosion/Irritation Category 1 A (H314) Serious Eye Damage/Eye Irritation Category 1 (H318) Specific target organ toxicity - (single exposure) Category 3 (H335)
Environmental hazards
Based on available data, the classification criteria are not met
Hazard statements
see section 16 H335 - May cause respiratory irritation H314 - Causes severe skin burns and eye damage H301 + H331 - Toxic if swallowed or if inhaled EUH014 - Reacts violently with water
Signal word
Danger
Precautionary statements
P280 - Wear eye protection/ face protection P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P261 - Avoid breathing dust/fume/gas/mist/vapors/spray P402 + P404 - Store in a dry place. Store in a closed container
2.3 Other hazards
In accordance with Annex XIII of the REACH Regulation, inorganic substances do not require assessment Stench This product does not contain any known or suspected endocrine disruptors