Note: Ingredients listed on restricted chemical lists
EC/CAS
231-635-3/7664-41-7
Name of the chemical
ammonia
Concentration
Classification according to
General Information
Revision date
2013-03-22
Product name
Anhydrous ammonia
Chemical name
Anhydrous ammonia
CAS No.
7664-41-7
REACH No
01-2119488876-14
Emergency telephone
FINLAND
Icons in SDS
Company Information
company name
Oy Woikoski Ab
e-mail address of the competent person responsible for the Safety Data Sheet
info@woikoski.fi
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H221, H280, H314, H331, H400
Hazard statements
Code
Statements
H221
Flammable gas
Section 2
CLP CLASSIFICATION
Flam. Gas 2 H221 Liquefied gas H280 Acute Tox. 3 (Inhalation:gas) H331 Skin Corr. 1B H314 Aquatic Acute 1 H400
EU Classification
Directive 67/548/EEC or 1999/45/EC T; R23 C; R34 N; R50 R10
2.2 Label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP]
Hazard pictograms
GHS06 GHS05 GHS04 GHS09
Signal word
Danger
Hazard statements
H221 - Flammable gas H280 - Contains gas under pressure; may explode if heated H314 - Causes severe skin burns and eye damage H331 - Toxic if inhaled H400 - Very toxic to aquatic life EUH071 - Corrosive to the respiratory tract
Precautionary statements
P210 - Keep away from heat/sparks/open flames/hot surfaces. - No smoking P260 - Do not breathe gas, vapours. P273 - Avoid release to the environment P280 - Wear protective gloves/protective clothing/eye protection/face protection P303+P361+P353+P315 - IF ON SKIN : (or hair) Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Get immediate medical advice / attention. P304+P340+P315 - IF INHALED : Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get immediate medical advice / attention. P305+P351+P338+P315 - IF IN EYES : Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get immediate medical advice / attention. P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely P381 - In case of leaking gas fire, eliminate all ignition sources if safe to do so P403 - Store in a well-ventilated place P405 - Store locked up
2.3 Other hazards