Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-82-1
Name of the chemical
Naphtha (petroleum), hydrodesulfurized heavy
Concentration
46%
General Information
Revision date
2015-01-09
Product name
ORGANO Zn 10
REACH No
The
1.2.1 Relevant identified uses
See Section 7.3
Icons in SDS
Company Information
company name
ORGANOMETAL SA
e-mail address of the competent person responsible for the Safety Data Sheet
info@organometal.gr, sales@organometa.gr
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H226, H304, H315, H319, H336, H361, H361d, H372, H411
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
Flammable liquids, Category 3 H226: Flammable liquid and vapour. Aspiration Toxicity Category 1 H304: May be fatal if swallowed and enters airways. Skin irritation, Category 2 H315: Causes skin irritation. Eye irritation, Category 2 H319: Causes serious eye irritation. Reproductive Toxicity Category 2 H361: Suspected of damaging fertility or the unborn child. (H361d) STOT SE 3 H336: May cause drowsiness or dizziness. STOT RE 1 H372: Causes damage to organs through prolonged or repeated exposure. Aquatic Chronic 2 H411: Toxic to aquatic life with long lasting effects. EUH066 Repeated exposure may cause skin dryness or cracking
2.2 Label elements
REGULATION (EC) No 1272/2008)
Hazard pictograms
GHS02 GHS08 GHS07 GHS09
Signal word
Danger
Hazard statements
H226: Flammable liquid and vapour. H304: May be fatal if swallowed and enters airways. H315 : Causes skin irritation H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness H361: Suspected of damaging fertility or the unborn child. (H361d) H372: Causes damage to organs through prolonged or repeated exposure. H411: Toxic to aquatic life with long lasting effects EUH066 Repeated exposure may cause skin dryness or cracking
Precautionary statements
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P240 Ground/bond container and receiνing equipment. P241Use explosion-proof electrical/νentilating/lighting/ ... / equipment. P243 Take precautionary measures against static discharge.
Response
P201: Obtain special instructions before use. P280: Wear protective gloves/protective clothing/eye protection/face protection. P281: Use personal protective equipment as required. P310: Immediately call a POISON CENTER or doctor/physician. P305+P351+P338 IF IN EYES Rinse cautiously with water for several minutes P308+P313 IF exposed or concerned Get medical advice/attention P370 + P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam for extinction
Storage
P403 + P235 + P233 Store in a well-ventilated place. Keep container tightly closed. Keep cool.
Disposal
P501 Dispose of container to an authorised company for waste treatment