Note: Ingredients listed on restricted chemical lists
EC/CAS
64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy; Low boiling point hydrogen treated naphtha (A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C6 through C13 and boiling in the range of approximately 65 °C to 230 °C.)
Concentration
N/A
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
General Information
Revision date
2012-06-08
Product name
Water & Oil Repellent RP220, Penetrating Concrete Sealer
1.2.1 Relevant identified uses
Impregnations, stain and soil repellent
Emergency telephone
In the event of emergency human exposure contact the Poisons
Icons in SDS
Company Information
company name
On-Crete Australia Pty Ltd
Section 2
2.1 Classification of the substance or mixture
Classified as hazardous according to criteria of NOHSC Classified as Hazardous according to the criteria of the New Zealand HSNO Act ERMA Number: HSR002495 Haz Classes: 3.1C, 6.4A, 9.1C Group Standard: Additives, Process Chemicals & Raw Materials (Flammable)
Hazard statements
Classified as hazardous according to criteria of NOHSC R10 Flammable. R65 Harmful: May cause lung damage if swallowed. R36 Irritating to eyes. R52/53 Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment. R66 Repeated exposure may cause skin dryness and cracking. R67 Vapours may cause drowsiness and dizziness
Precautionary statements
S2, S9, S25, S26, S43, S60, S61 - Keep put of reach of children. Keep container in a well ventilated place. Avoid contact with eyes. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. In case of fire use sand, dry chemical or alcohol resistant foam. This material and its container must be disposed of as hazardous waste. Avoid
Potential health effects
Inhalation of decomposition products in high concentration may cause shortness of breath (lung oedema). Inhalation of aerosol or fine spray mist may cause serious respiratory problems.