Note: Ingredients listed on restricted chemical lists
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
99.99
General Information
Revision date
2018-09-27
Product name
Gamma Ray Standard, Uranium
1.2.1 Relevant identified uses
Calibration of Gamma Ray Sensors
Emergency telephone
1-800-535-5053, 1-352-323-3500
Icons in SDS
Company Information
company name
OFI Testing Equipment, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H335, H350, H372
Hazard statements
Code
Statements
H335
May cause respiratory irritation
Section 2
Classification (GHS-US)
Carc. 1A H350 STOT SE 3 H335 STOT RE 1 H372
Hazard statements
see section 16 : H335 - May cause respiratory irritation. H350 - May cause cancer (Inhalation). H372 - Causes damage to organs (Lungs) through prolonged or repeated exposure (Inhalation).
2.2 Label elements
GHS-US Labeling
Hazard pictograms
GHS07 GHS08
Signal word
Danger
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P260 - Do not breathe dust. P264 - Wash hands, forearms, and exposed areas thoroughly after handling. P270 - Do not eat, drink or smoke when using this product. P271 - Use only outdoors or in a well-ventilated area. P280 - Wear protective clothing, respiratory protection. P304+P340 - If inhaled: Remove person to fresh air and keep at rest in a position comfortable for breathing. P308+P313 - If exposed or concerned: Get medical advice/attention. P312 - Call a POISON CENTER, a doctor if you feel unwell. P314 - Get medical advice/attention if you feel unwell. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. P405 - Store locked up. P501 - Dispose of contents/container in accordance with local, regional, national, and international regulations.
2.3 Other hazards
Exposure may aggravate those with pre-existing eye, skin, or respiratory conditions. 2.4.
Ingredient(s) with unknown acute toxicity
No data available