- Weldfast CL-200 Part B

NOV Fiber Glass Systems

Revision date : 2015-05-18

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS03 GHS05
Health risk rating 3
Safety risk rating 4
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

231-765-0

Name of the chemical

Hydrogen peroxide and other compounds or mixtures that release hydrogen peroxide, including carbamide peroxide and zinc peroxide, with the exception of the following substances in Annex II: — No 1397, 1398, 1399

Concentration

<2

General Information

Revision date

2015-05-18

Product name

- Weldfast CL-200 Part B

Emergency telephone

1-888-298-2344, 1-760-476-3960, 1-760-476-3961, 1-760-476-3962

Icons in SDS

GHS03 GHS05

Company Information

company name

NOV Fiber Glass Systems

e-mail address of the competent person responsible for the Safety Data Sheet

Mike.Thayer@nov.com

GHS Information

Signal word

-

Hazard Codes

Hazard statements (CLP)

H242, H302, H313, H314, H332, H402

Hazard statements

Code

Statements

H242

Heating may cause a fire

Section 2

SECTION 2: Hazards identification

Classification of the substance or mixture Physical Organic peroxide, Type D Health Acute toxicity, Category 4 (inhalation) Acute toxicity, Category 4 (oral) Acute toxicity, Category 5 (dermal) Eye irritation, Category 1 Skin corrosion/irritation, Category 1B 2014 National Oilwell Varco. All rights reserved SDS4205ENGB August 2014 Environmental Acute aquatic toxicity, Category 3

Signal word

- DANGER

Hazard statements

- Physical • H242: Heating may cause a fire. - Health • H302: Harmful if swallowed. • H313: May be harmful in contact with skin. • H314: Causes severe skin burns and eye damage. • H332: Harmful if inhaled. - Environmental • H402: Harmful to aquatic life.

Precautionary statements

-

Prevention

• P210: Keep away from heat/sparks/open flames/hot surfaces; no smoking. • P234: Keep only in original packaging. • P260: Do not breathe vapors. • P264: Wash skin and contaminated skin thoroughly after handling. • P270: Do not eat, drink or smoke when using this product. • P271: Use only outdoors or in well-ventilated area. • P273: Avoid release to the environment. • P280: Wear protective gloves/protective clothing/eye protection/face protection. -

Response

• P301+P330+P331 IF SWALLOWED Rinse mouth. DO NOT induce vomiting • P303+P361+P353 IF ON SKIN (or hair) Take off immediately all contaminated clothing. Rinse skin with water/shower. • P304+P340 IF INHALED Remove person to fresh air and keep comfortable for breathing • P305+P351+P338 IF IN EYES Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. • P310: Immediately call a POISON CENTER or doctor/physician if swallowed or in eyes. • P378: Use water spray, foam, sand, dry chemical powder or carbon dioxide to extinguish. Page 2 of 17 -

Storage

• P403: Store in a well-ventilated place. • P410: Protect from sunlight. -

Disposal

• P501: Dispose of contents/container in accordance with regulatory requirements.

2.3 Other hazards

-

Results of PBT and vPvB assessment

• None of the ingredients are considered to be either PBT or vPvB.

2.1 Classification of the substance or mixture

Physical - Organic peroxide, Type D Health - Acute toxicity, Category 4 (inhalation) - Acute toxicity, Category 4 (oral) - Acute toxicity, Category 5 (dermal) - Eye irritation, Category 1 - Skin corrosion/irritation, Category 1B © 2014 National Oilwell Varco. All rights reserved SDS4205ENGB August 2014 Environmental - Acute aquatic toxicity, Category 3

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.