GreensandPlusTM is a specially selected granular substrate with a manganese dioxide coating used for water purification - the removal of

Northern Filter Media, Inc

Revision date : 2017-08-15

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

1313-13-9

Name of the chemical

Manganese dioxide

Concentration

3.2-4.8 3.2-4.8

Listed in

EC/CAS

14808-60-7

Name of the chemical

Silica, crystalline

Concentration

90.4-93.6

General Information

Revision date

2017-08-15

Product name

GreensandPlusTM is a specially selected granular substrate with a manganese dioxide coating used for water purification - the removal of

Product Synonyms

No product synonyms. (For ingredient synonyms, see SECTION 3

CAS No.

Mixture

1.2.1 Relevant identified uses

heavy metals and sulfur compounds

supplier name

Northern Filter Media, Inc

Emergency telephone

contact 563-263-2711

Icons in SDS

Company Information

company name

Northern Filter Media, Inc

e-mail address of the competent person responsible for the Safety Data Sheet

info@northernfiltermedia.com

Section 2

SECTION 2: Hazards identification

OSHA Emergency Overview: Not a fire or spill hazard. Low toxicity, dry dust is a nuisance particulate. Generally, health effects are provided for exposure to dust that may be generated during product transfer and handling. OHSA ACGIH TLV NIOSH REL LISTED CARCINOGEN Component Percentage (YES/NO) (by wgt.) PEL CEILING TWA STEL TWA STEL NTP IARC OSHA (mg/m3) Manganese 3.2-4.8. N/A 5F NL 1 3 NO Dioxide (MnO2) (as Mn) Nonhazardous 3.2-4.8. 1S T; S NL 10 T; NL NO Ingredients / 5R Inert Materials / Proprietary Quartz (SiO2) 90.4-93.6 10/(% NL 0.025 0.1 0.05 NL YES SiO2+2) Notes: T Total Dust; R = Respirable dust, F = Fume 1. Exposure limits listed for each ingredient is for exposure to dust that may be generated during product transfer and handling. 2. Solid Manganese: 0.35-1.00 mm is formulated for use in water purification. Health effects resulting from this product being used for any other purpose of process is not addressed in the material safety data sheet. 3. NTP Class 2A: Reasonably anticipated to be a carcinogen limited evidence of carcinogenicity from studies in humans. 4. IARC Group 2A: Probably carcinogenic to humans. 5. NIOSH considers crystalline silica to be a potential occupational carcinogen as defined by the OSHA carcinogen policy [29 cfr 1990].

Principle Routes of Exposure

Inhalation Eye Contact: Contact with particulate may cause slight to moderate eye irritation. Abrasive action of dust particulate can damage eye. Skin Contact: Prolonged or repeated contact may cause slight to moderate skin irritation. Inhalation: Overexposure by inhalation of airborne particulate, dust, or fumes is irritating to the nose, throat, and respiratory tract. Inhalation of excessive levels of dust or fumes may be harmful. Ingestion: Ingestion is an unlikely route of exposure; no hazard in normal industrial use. Small amounts (<tablespoon) swallowed during normal handling operations are not likely to cause injury, however, swallowing larger amounts may cause injury. If ingested, quantity may cause gastrointestinal disturbances. Symptoms may include irritation, nausea, vomiting, abdominal pain, and diarrhea. Target Organs: Respiratory system, eyes, central nervous system. Acute Effects of Exposure: Excessive, short term exposure to airborne mineral dusts and particulate may cause upper respiratory and eye irritation. Exposure via inhalation to high concentration of dusts containing manganese compounds for as little as three months have affected the central nervous system.

Potential chronic health

of exposure Excessive, long-term, inhalation of airborne mineral dusts and particulate may contribute to the development of bronchitis, reduced breathing capacity, and may lead to the increased susceptibility to lung disease. Manganese poisoning: The excessive, chronic inhalation of manganese compounds usually begins with complaints of languor and sleepiness. This is followed by weakness in the legs and the development of stolid, mask-like faces. The patient speaks with a slow monotonous voice. Then muscular twitching appears, varying from a fine tremor of the hands to coarse, rhythmical movements of the arms, legs, and trunk. There is a slight increase in tendon reflexes, ankle and patellar clonus, and a typical Parkinsonian slapping gate. Silicosis has been associated with an increased risk of lung cancer, autoimmune and chronic kidney diseases, tuberculosis and non-malignant respiratory diseases. Crystalline silica should be considered a possible human carcinogen based on this association. Fused silica has not been identified as a carcinogen. Signs and Symptoms of exposure: (Dust) tearing of eyes, burning sensation in the throat, cough, and chest discomfort. Medical Conditions Generally Known to be Aggravated by Exposure: The excessive inhalation of mineral dust may aggravate pre-existing chronic lung conditions such as, but not limited to, bronchitis, emphysema, and asthma. Reproductive Hazards: Not a reproductive hazard.

Environmental effects

Derived from natural ores; no adverse known. However, prevent spilled product from entering streams, water bodies, and wastewater systems. This material is used as an agricultural product.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.