Note: Ingredients listed on restricted chemical lists
EC/CAS
231-157-5/7440-47-3
Name of the chemical
Chromium‡
Concentration
3 - 6
EC/CAS
231-158-0/7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
0.5 - 10
EC/CAS
231-153-3/7440-44-0
Name of the chemical
Carbon black
Concentration
0.5 - 2
EC/CAS
231-111-4/7440-02-0
Name of the chemical
Nickel
Concentration
0 - 0.5
General Information
Revision date
2012-06-11
Product name
KC300, KP6520, KP6525, KP6505, KM6515, KSN38, KSP21, KSN25, KSN28, KSSH22, KSH26, KSU50, KSU52, KSU59, M1, M2, M3-2, M3-2+Co, M4, M7, M35, M42, M50, T15, PM T15 mod
Product Synonyms
Not applicable
Chemical name
Not applicable
1.2.1 Relevant identified uses
High-speed steels (HSS) for cutting tool application
Emergency telephone
+49-911-9735-0, +1-703-527-3887
Icons in SDS
Company Information
company name
North America (NA)
GHS Information
Signal word
WARNING!
Section 2
SECTION 2: Hazards identification
WARNING! Fragmentation hazard. Cutting tools and holders may fragment in use. Always wear safety equipment and keep machine guards in place. Breathing hazard. Wet or dry grinding of cutting tools may produce hazardous dust or mist. Use ventilation control and respiratory protection. Do not re-sharpen tools without using appropriate safety and extraction systems to avoid dust exposure. Return tools to Kennametal for reconditioning services. CLASSIFICATION AND LABELING FOR ARTICLE FORM: GHS STATUS: Not regulated as product is an article under prescribed conditions of use. OSHA/WHMIS REGULATORY STATUS: Not regulated as product is an article under prescribed conditions of use. EU (per EEC
Hazard pictograms
Directive None required as product is an article under prescribed conditions of use. 1999/45/EEC): Phrases: None required as product is an article under prescribed conditions of use. HUMAN THRESHOLD RESPONSE DATA: NIOSH Immediately Dangerous to Life or The IDLH for this product is not known. The IDLHs for ingredients are: Health (IDLH) Value(s): 10 mg/m3 for nickel; 20 mg/m3 for cobalt; 250 mg/mg3 for chromium and 5000 mg/m3 for molybdenum.
Potential health effects
As a sintered tool, exposure to high volumes of powder/dust is not anticipated under normal conditions and use. If tool chips, breaks, fragments or is reground, exposure to powder/dust may result in potential health effects. ACUTE EFFECTS: Eye: Dusts generated from grinding may cause mechanical irritation of the eye. Skin: Dusts generated from grinding may cause mechanical irritation of the skin. Inhalation: Dusts generated from grinding may cause mechanical irritation of the respiratory tract. Ingestion: Ingestion of dusts generated from grinding is not expected, There are no known effects. Page 2 of 17 HAZARDS IDENTIFICATION (CONT’D)
Potential chronic health
Prolonged or repeated inhalation of powder, dust or fume may cause severe respiratory irritation and possibly lung damage, may lead to the development of permanent, severe, obstructive or fibrotic lung disease characterized by coughing, wheezing, shortness of breath and extreme breathing difficulty in sensitized individuals. Repeated contact with powder or dust may cause an allergic skin reaction consisting of itching, redness, swelling, and rash or urticaria (hives) in sensitized individuals. Nickel has been classified as a Group 2B carcinogen - Possibly carcinogenic to humans – by the International Agency for Research on Cancer (IARC).
Medical Conditions Generally Aggravated by Exposure
None known.
Environmental effects
None known.