Note: Ingredients listed on restricted chemical lists
EC/CAS
231-158-0/7440-48-4
Name of the chemical
Cobalt, Metall (2020/217)
Concentration
<25%
General Information
Revision date
2013-03-22
Product name
02F,2608, A30, AM20, AM40, B08, B09, B10, B25, B30, B55, BT10, BT15, BT25, BT30, BT40G, BT45, CBN6, CG55, CM1, CPD1 G13, G15, G20, GT30, GT55, K05, K20TIALN, K313, K322, KC410M, KC520M, KC522M, KC5020P, KC6005, KC6305, KC639M, KC725M, KC7220, KC7315, KC7425, KCK15, KCPK30, KCMP30, KCPM20, KCSM15, KCU32, KCU33, KCU36, KCU45, KF1, KF315, KMF, KMH, KMS, P5M, PF1, PK120, S105-KMS, S113-PFC, S114-KXC, S105, S116, SP0A00, SP0B00, SP0G00, SP0M00, SP0N00, THA-S, THA-U, THF, THG, THM (1.8%), THM (2.5%), THM-F, TH...
Product Synonyms
Hard Metal, Cemented WC, Tungsten Carbide
Chemical name
Tungsten Carbide product with Cobalt binder
1.2.1 Relevant identified uses
Mining Tools, Construction Tools, Round Tools, Metalworking Tools, Metallurgical Products, Powders and Inserts
Emergency telephone
+49-911-9735-0, +1-703-527-3887
Icons in SDS
Company Information
company name
North America (NA)
Section 2
SECTION 2: Hazards identification
WARNING Fragmentation hazard. Cutting tools and holders may fragment in use. Always wear safety equipment and keep machine guards in place. Breathing hazard. Wet or dry grinding of cutting tools may produce hazardous dust or mist. Use ventilation control and respiratory protection. Do not re-sharpen tools without using appropriate safety and extraction systems to avoid dust exposure. Return tools to Kennametal for reconditioning services. CLASSIFICATION AND LABELING FOR MASSIVE FORM GHS STATUS Not regulated as product is an article under prescribed conditions of use. OSHA/WHMIS REGULATORY Not regulated as product is an article under prescribed conditions of use. STATUS: EU (per EEC Danger Directive 1999/45/EEC)
Hazard pictograms
None required as product is an article under prescribed conditions of use Phrases: None required as product is an article under prescribed conditions of use. HUMAN THRESHOLD RESPONSE DATA: Page 2 of 10 NIOSH Immediately Dangerous to Life or Health (IDLH) Value(s): The IDLH for this product is not known. The IDLH for cobalt is 20 mg/m3. (CONT’D)
Potential health effects
As a sintered tool, exposure to high volumes of powder/dust is not anticipated under normal conditions and use. If tool chips, breaks, fragments or is reground, exposure to powder/dust may result in potential health effects. ACUTE EFFECTS Eye Powder or dust may cause irritation consisting of redness, swelling, and pain. May cause conjunctivitis with repeated exposures. Skin Material not expected to be absorbed through the skin. Contact with dust or powder may cause irritation consisting of redness and/or swelling. Sensitized persons may experience an allergic reaction when exposed to cobalt. Inhalation Material not expected to be inhaled in high concentrations. Inhalation of high concentrations of powder, dust, or fume may cause respiratory and nasal irritation, coughing, and difficulty breathing. Ingestion Material not expected to be ingested. Ingestion of large amounts of dust or powder may cause nausea, diarrhea and/or stomach pain.
Potential chronic health
Prolonged or repeated skin contact with powder or dust may cause severe irritation or dermatitis. Prolonged or repeated inhalation of powder, dust or fume may cause severe irritation and possibly lung damage. Chronic exposure to dust or powder may also lead to the development of permanent, severe, obstructive or fibrotic lung disease characterized by coughing, wheezing, and shortness of breath. Repeated contact with powder or dust may cause an allergic skin reaction consisting of itching, redness, swelling, and rash or urticaria (hives) in sensitized individuals. Prolonged or repeated inhalation of powder, dust or fume may cause an allergic type of asthma reaction characterized by wheezing, coughing, and extreme breathing difficulty in sensitized individuals. IARC lists cobalt metal with tungsten carbide as probably carcinogenic to humans (Group 2A)
Medical Conditions Generally Aggravated by Exposure
Exposure to dust or powder may aggravate existing dermatitis, asthma, emphysema, and other respiratory disease.
Environmental effects
None known. Product has not been tested for environmental properties.