Note: Ingredients listed on restricted chemical lists
EC/CAS
231-157-5/7440-47-3
Name of the chemical
Chromium‡
Concentration
10 - 40
EC/CAS
236-675-5/13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
5 - 15
EC/CAS
231-111-4/7440-02-0
Name of the chemical
Nickel
Concentration
5 - 15
EC/CAS
238-878-4/14808-60-7
Name of the chemical
Silica, crystalline
Concentration
5 - 15
EC/CAS
215-691-6/1344-28-1
Name of the chemical
aluminium oxide
Concentration
2 - 8
EC/CAS
231-105-1/7439-96-5
Name of the chemical
Manganese
Concentration
<2.5
General Information
Revision date
2022-01-13
Product name
NST INOX flux cored wires
Product Synonyms
NST A-316L / A-309MoL / A-309L / A-308L/FCW A625 / 316LT/309MoLT / 309LT/308LT / 329J3L
Emergency telephone
Comment
Icons in SDS
Company Information
company name
Norsk Sveiseteknikk AS
e-mail address of the competent person responsible for the Safety Data Sheet
Thomas@nst.no - nst.no
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H317, H351, H372
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
H351
Suspected of causing cancer
H372
Causes damage to organs through prolonged or repeated exposure
Section 2
CLP CLASSIFICATION
Skin Sens. 1 H317 Carc. 2 H351 STOT RE 1 H372
Hazard statements
see section 16
Adverse physicochemical, human health and environmental effects
No additional information available
2.2 Label elements
Labelling according to Regulation (EC) No. 1272/2008 [CLP]
Contains
Nickel
Supplemental label elements
EUH212 - Warning! Hazardous respirable dust may be formed when used. Do not breathe dust. EUH210 - Safety data sheet available on request.
Additional information
Alloys in massive form do not need to be labeled acc. CLP Regulation (1272/2008), art. 23 (d) and Annex I 1.3.4. These complex alloys in massive form have no known toxicological properties other than causing allergic reactions in individuals sensitive to the metals contained in the alloys. Hazardous fume or dust emissions may be released during remelting, grinding, cutting or welding.
Other hazards which do not result in classification
In the smoke emitted during use, there will be an additional risks if inhaled. Intensive exposure to welding fumes may cause lung disease, bronchitis, or worsen already existing inhalation problems. Intensified exposure to manganese (Mn) can damage the central nervous system or worsen existing health problems. This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII The mixture does not contain substance(s) included in the list established in accordance with Article 59(1) of REACH for having endocrine disrupting properties, or is not identified as having endocrine disrupting properties in accordance with the criteria set out in Commission Delegated Regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605