Note: Ingredients listed on restricted chemical lists
EC/CAS
231-157-5/7440-47-3
Name of the chemical
Chromium; chromic acid and its salts
Concentration
<1
EC/CAS
215-691-6/1344-28-1
Name of the chemical
aluminium oxide
Concentration
<1
EC/CAS
231-768-7/7723-14-0
Name of the chemical
Phosphorus
Concentration
<0.5
EC/CAS
238-878-4/14808-60-7
Name of the chemical
Silica, crystalline
Concentration
1-15
EC/CAS
231-153-3/7440-44-0
Name of the chemical
Carbon black
Concentration
<0.5
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
<0.5
EC/CAS
231-105-1/7440-02-0
Name of the chemical
Nickel
Concentration
N/A
EC/CAS
236-675-5/13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
2-10 <5
EC/CAS
231-111-4
Name of the chemical
Nickel
Concentration
< 3
General Information
Revision date
2017-06-23
Product name
NSSW Flux Cored Wires
Product Synonyms
SF-1A, SF-1E, SF-3A, SF-3M, SF-3AM, SF-3AMSR, SF-3E, SF-36E, SF-36EA, SM-3A, SF- 50A, NSSW SF-80A, NSSW SF-47E, NSSW SF-50E, NSSW SF-80A, NSSW SM-80A
Icons in SDS
Company Information
company name
Norsk Sveiseteknikk AS
e-mail address of the competent person responsible for the Safety Data Sheet
Eyvind@nst.no
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H317, H351, H373
Hazard statements
Code
Statements
H317
May cause an allergic skin reaction
H351
Suspected of causing cancer
H373
May cause damage to organs through prolonged or repeated exposure
Section 2
CLP CLASSIFICATION
Skin Sens. 1 H317 Carc. 2 H351 STOT RE 2 H373
Hazard statements
see section 16
2.2 Label elements
Alloy. According to EC directives or the corresponding national regulations there is no labelling obligation for this product.
Other hazards which do not result in classification
In the smoke emitted by use, there will be am additional risks if inhaled. Intensive exposure to welding fumes may cause lung disease, bronchitis, or worsen already existing inhalation problems. Intensified exposure to manganese (Mn) can damage the central nervous system or worsen existing health problems. This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII